Back to Search Start Over

D-SUN Method to Prevent Double-Bubble Deformity in Broad Base Breasts with High-Rising Inframammary Fold.

Authors :
Fertsch S
Wolter A
Rancati A
Andree C
Source :
Aesthetic plastic surgery [Aesthetic Plast Surg] 2020 Jun; Vol. 44 (3), pp. 637-647. Date of Electronic Publication: 2020 Feb 28.
Publication Year :
2020

Abstract

Breast augmentation is the most commonly performed plastic surgery among women worldwide. With time, implant selection shifted from arbitrary implantation to precise planning. Different methods address the dimensional planning process. Many of them are complex to put into practice, focusing mainly on the breast base. Constricted, short lower pole breasts are morphologically predisposed to complication such as double-bubble deformity. Yet, by focusing on the distance between the nipple on stretch and the inframammary fold, the D-SUN method guides the surgeon to find the most appropriate implant volume for anatomical form-stable silicon implants and IMF incision to avoid complications.Level of evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.

Details

Language :
English
ISSN :
1432-5241
Volume :
44
Issue :
3
Database :
MEDLINE
Journal :
Aesthetic plastic surgery
Publication Type :
Academic Journal
Accession number :
32112195
Full Text :