Back to Search Start Over

What Do We Do After the Pilot Is Done? Implementation of a Hospital Early Warning System at Scale.

Authors :
Paulson SS
Dummett BA
Green J
Scruth E
Reyes V
Escobar GJ
Source :
Joint Commission journal on quality and patient safety [Jt Comm J Qual Patient Saf] 2020 Apr; Vol. 46 (4), pp. 207-216. Date of Electronic Publication: 2020 Jan 21.
Publication Year :
2020

Abstract

Background: Adults who deteriorate outside the ICU have high mortality. Most rapid response systems (RRSs) have employed manual detection processes that rapid response teams (RRTs) use to identify patients at risk. This project piloted the use of an automated early warning system (EWS), based on a very large database, that provides RRTs with 12 hours lead time to mount a response. Results from a 2-hospital pilot were encouraging, so leadership decided to deploy the Advance Alert Monitor (AAM) program in 19 more hospitals.<br />Challenge: How can one deploy an RRS using an automated EWS at scale?<br />Solution: EWS displays were removed from frontline clinicians' hospital electronic dashboards, and a Virtual Quality Team (VQT) RN was interposed between the EWS and the RRT. VQT RNs monitor the EWS remotely-when alerts are issued, they conduct a preliminary chart review and contact hospital RRT RNs. VQT and RRT RNs review the cases jointly. The RRT RNs then consult with hospitalists regarding clinical rescue and/or palliative care workflows. Subsequently, VQT RNs monitor patient charts, ensuring adherence to RRS practice standards. To enable this process, the project team developed a governance structure, clinical workflows, palliative care workflows, and documentation standards.<br />Results: The AAM Program now functions in 21 Kaiser Permanente Northern California hospitals. VQT RNs monitor EWS alerts 24 hours a day, 7 days a week. The AAM Program handles ∼16,000 alerts per year. Its implementation has resulted in standardization of RRT staffing, clinical rescue workflows, and in-hospital palliative care.<br /> (Copyright © 2020 The Author(s). Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1938-131X
Volume :
46
Issue :
4
Database :
MEDLINE
Journal :
Joint Commission journal on quality and patient safety
Publication Type :
Academic Journal
Accession number :
32085952
Full Text :
https://doi.org/10.1016/j.jcjq.2020.01.003