Comparison between two different next generation sequencing platforms for clinical relevant gene mutation test in solid tumours.
- Source :
-
Journal of clinical pathology [J Clin Pathol] 2020 Sep; Vol. 73 (9), pp. 602-604. Date of Electronic Publication: 2020 Feb 14. - Publication Year :
- 2020
-
Abstract
- In the present study, we analysed 44 formalin fixed paraffin embedded (FFPE) from different solid tumours by adopting two different next generation sequencing platforms: GeneReader (QIAGEN, Hilden, Germany) and Ion Torrent (Thermo Fisher Scientific, Waltham, Massachusetts, USA). We highlighted a 100% concordance between the platforms. In addition, focusing on variant detection, we evaluated a very good agreement between the two tests (Cohen's kappa=0.84) and, when taking into account variant allele fraction value for each variant, a very high concordance was obtained (Pearson's r=0.94). Our results underlined the high performance rate of GeneReader on FFPE samples and its suitability in routine molecular predictive practice.<br />Competing Interests: Competing interests: None declared.<br /> (© Author(s) (or their employer(s)) 2020. No commercial re-use. See rights and permissions. Published by BMJ.)