Back to Search Start Over

Interlaboratory analysis of teicoplanin plasma concentration assays among Chinese laboratories.

Authors :
Wang XX
Jin PF
Li PM
Xu S
Kong XD
Qin W
Chen WQ
Qin WJ
Zhang XL
Source :
Journal of clinical pharmacy and therapeutics [J Clin Pharm Ther] 2020 Oct; Vol. 45 (5), pp. 983-990. Date of Electronic Publication: 2020 Jan 27.
Publication Year :
2020

Abstract

What Is Known and Objective: Teicoplanin is widely used for the treatment of infections caused by drug-resistant Gram-positive bacteria. Since there is a good correlation between trough levels and clinical outcome, therapeutic drug monitoring (TDM) is recommended to achieve better clinical curative effects. However, TDM of teicoplanin is not routine in China. So, a programme was initiated in 2017, including both HPLC method establishment and interlaboratory quality assessment, for the measurement of teicoplanin.<br />Methods: A main centre and a quality control centre were set up in the study. An HPLC-based method of teicoplanin determination in plasma was developed by the main centre. Analysis was performed using a Waters Symmetry C18 column (250 mm × 4.6 mm, 5 µm). The mobile phase was NaH <subscript>2</subscript> PO <subscript>4</subscript> (0.01 mol/L) and acetonitrile (75:25 v/v; pH 3.3), with a flow rate of 1.0 mL/min and a detection wavelength of 215 nm. Piperacillin sodium was selected as an internal standard (IS). Twenty-six additional TDM centres were then recruited to adopt this method. Then, all the centres were asked to take part in a quality control assessment evaluated by the quality control centre.<br />Results: For all TDM centres, linearity of teicoplanin concentration ranges was between 3.125 and 100 µg/mL. Intraday and interday accuracies ranged from 87.1% to 118.4%. Intraday and interday precision ranged from 0.3% to 13.8%. Therapeutic drug monitoring centres all passed inter-room quality assessment. All samples tested met the acceptance criteria. Then, 542 samples were collected. Patients with sub-optimal (≤10 mg/L) plasma teicoplanin concentrations constituted 42% of the total study population.<br />What Is New and Conclusions: For the first time, a simple, rapid and accurate HPLC method for determining teicoplanin levels was successfully applied to therapeutic drug monitoring in clinical practice for twenty-seven TDM centres in China. The results demonstrated excellent interlaboratory agreement for teicoplanin testing and provide support for clinical laboratory quality management and results inter-accreditation.<br /> (© 2020 John Wiley & Sons Ltd.)

Details

Language :
English
ISSN :
1365-2710
Volume :
45
Issue :
5
Database :
MEDLINE
Journal :
Journal of clinical pharmacy and therapeutics
Publication Type :
Academic Journal
Accession number :
31985852
Full Text :
https://doi.org/10.1111/jcpt.13115