Biomechanical Study of a Multifilament Stainless Steel Cable Crimp System Versus a Multistrand Ultra-High Molecular Weight Polyethylene Polyester Suture Krackow Technique for Achilles Tendon Rupture Repair.

Authors :
Nguyen TP
Keyt LK
Herfat S
Gordon L
Palanca A
Source :
The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons [J Foot Ankle Surg] 2020 Jan - Feb; Vol. 59 (1), pp. 86-90.
Publication Year :
2020

Abstract

Currently, Achilles tendon rupture repair is surgically addressed with an open or minimally invasive approach using a heavy, nonabsorbable suture in a locking stitch configuration. However, these sutures have low stiffness and a propensity to stretch, which can result in gapping at the repair site. Our study compares a new multifilament stainless steel cable-crimp repair method to a standard Krackow repair using multistrand, ultra-high molecular weight polyethylene polyester sutures. Eight matched pairs of cadavers were randomly assigned for Achilles tendon repair using either Krackow technique with polyethylene polyester sutures or the multifilament stainless steel cable-crimp technique. Each repair was cyclically loaded from 10 to 50 N for 100 loading cycles, followed by a linear increase in load until complete failure of the repair. During cyclic loading, 4 of the 8 Krackow polyethylene polyester suture repairs failed, whereas none of the multifilament stainless steel cable crimp repairs failed. Load to failure was greater for the multifilament stainless steel cable crimp repairs (321.03 ± 118.71 N) than for the Krackow polyethylene polyester suture repairs (132.47 ± 103.39 N, p = .0078). The ultimate tensile strength of the multifilament stainless steel cable crimp repairs was also greater than that of the Krackow polyethylene polyester suture repairs (485.69 ± 47.93 N vs 378.71 ± 107.23 N, respectively, p = .12). The mode of failure was by suture breakage at the crimp for all cable-crimp repairs and by suture breakage at the knot, within the tendon, or suture pullout for the polyethylene polyester suture repairs. The multifilament stainless steel cable crimp construct may be a better alternative for Achilles tendon rupture repairs.<br /> (Copyright © 2019 the American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1542-2224
Volume :
59
Issue :
1
Database :
MEDLINE
Journal :
The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons
Publication Type :
Academic Journal
Accession number :
31882153
Full Text :
https://doi.org/10.1053/j.jfas.2019.01.022