Abstract

Objective: To report the early and mid-term results of patients who underwent minimally invasive aortic valve replacement (MI-AVR) with a sutureless prosthesis from an international prospective registry.<br />Methods: Between March 2011 and September 2018, among 957 patients included in the prospective observational SURE-AVR (Sorin Universal REgistry on Aortic Valve Replacement) registry, 480 patients underwent MI-AVR with self-expandable Perceval aortic bioprosthesis (LivaNova PLC, London, UK) in 29 international institutions through either minithoracotomy ( n = 266) or ministernotomy ( n = 214). Postoperative, follow-up, and echocardiographic outcomes were analyzed for all patients.<br />Results: Patient age was 76.1 ± 7.1 years; 64.4% were female. Median EuroSCORE I was 7.9% (interquartile range [IQR], 4.8 to 10.9). Median cardiopulmonary bypass and cross-clamp times were 81 minutes (IQR 64 to 100) and 51 minutes (IQR 40 to 63). First successful implantation was achieved in 97.9% of cases. Two in-hospital deaths occurred, 1 for noncardiovascular causes and 1 following a disabling stroke. In the early (≤30 days) period, stroke rate was 1.4%. Three early explants were reported: 2 due to nonstructural valve dysfunction (NSVD) and 1 for malpositioning. One mild and 1 moderate paravalvular leak were reported. In 16 patients (3.3%) pacemaker implantation was needed. Mean follow-up was 2.4 years (maximum = 7 years). During follow-up 5 explants were reported, 3 due to endocarditis and 2 due to NSVD. Follow-up stroke rate was 2.5%. Three structural valve deteriorations not requiring reintervention were reported. Five-year survival was 91.45%.<br />Conclusions: In this large prospective international registry, MI-AVR with Perceval valve confirmed to be safe, reproducible, and effective in an intermediate-risk population, providing excellent clinical recovery both in early and mid-term follow-up.

Details

Language :
English
ISSN :
1559-0879
Volume :
15
Issue :
2
Database :
MEDLINE
Journal :
Innovations (Philadelphia, Pa.)
Publication Type :
Academic Journal
Accession number :
31875777
Full Text :
https://doi.org/10.1177/1556984519892585