Back to Search
Start Over
Steerable Sheath for Cannulation and Bridging Stenting of Challenging Target Visceral Vessels in Fenestrated and Branched Endografting.
- Source :
-
Annals of vascular surgery [Ann Vasc Surg] 2020 Aug; Vol. 67, pp. 26-34. Date of Electronic Publication: 2019 Dec 16. - Publication Year :
- 2020
-
Abstract
- Background: To report the use of the Oscor Destino steerable sheath in challenging target visceral vessel (TVV) cannulation/bridging stenting in fenestrated and branched endovascular aneurysm repair (FB-EVAR).<br />Methods: Between 2016 and 2018, patients undergoing FB-EVAR for juxtarenal/pararenal aneurysms (j/p-AAAs) and thoracoabdominal aortic aneurysms (TAAAs) were recorded. Cases requiring the use of the steerable sheath as planned or unplanned maneuvers were analyzed. Technical success, freedom from reinterventions, and TVV patency were assessed.<br />Results: Two hundred sixty patients underwent FB-EVAR to treat j/p-AAAs and TAAAs, for an overall of 956 TVVs. Among these, the Oscor Destino steerable sheath was used in 33 (13%) cases to cannulate a total of 62 (7%) TVVs. FB-EVAR was performed for 7 (21%) j-AAAs, 4 (12%) p-AAAs, 11 (61%) TAAAs, and 2 (6%) previously failed EVAR. The TVVs were 37 (60%) renal arteries, 9 (15%) superior mesenteric arteries, and 16 (25%) celiac trunks. The Oscor Destino steerable sheath was used as the primary cannulation approach in 29 (47%) cases and after failure of the standard cannulation technique in 33 (53%) cases. Technical success was achieved in 61/62 (98%) TVVs. There was no 30-day mortality or bowel ischemia. At the discharge, there were no type I/III endoleaks, whereas 4 type II endoleaks were detected. The median follow-up was 12 months (interquartile range: 8). One patient died at 6 months because of aneurysm-unrelated cause. No TVV occlusion or TVV-related reinterventions occurred. There were no type I-III endoleaks.<br />Conclusions: The use of the steerable sheath could be an effective adjunctive tool and can be used primarily as a planned technique or in case of failure of the standard cannulation technique in challenging TVV anatomy during FB-EVAR.<br /> (Copyright © 2019 Elsevier Inc. All rights reserved.)
- Subjects :
- Aortic Aneurysm, Abdominal diagnostic imaging
Aortic Aneurysm, Abdominal physiopathology
Aortic Aneurysm, Thoracic diagnostic imaging
Aortic Aneurysm, Thoracic physiopathology
Blood Vessel Prosthesis Implantation adverse effects
Databases, Factual
Endovascular Procedures adverse effects
Female
Humans
Italy
Male
Postoperative Complications etiology
Prosthesis Design
Registries
Retrospective Studies
Time Factors
Treatment Outcome
Vascular Patency
Aortic Aneurysm, Abdominal surgery
Aortic Aneurysm, Thoracic surgery
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation instrumentation
Endovascular Procedures instrumentation
Stents
Vascular Access Devices
Subjects
Details
- Language :
- English
- ISSN :
- 1615-5947
- Volume :
- 67
- Database :
- MEDLINE
- Journal :
- Annals of vascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 31857228
- Full Text :