- Pre-surgical planning using 3D-printed BioModels enables the preparation of a "patient-specific" kit to assist instrumented spinal fusion surgery. This approach has the potential to decrease operating time while also offering logistical benefits and cost savings for healthcare. We report our experience with this method in 129 consecutive patients undergoing minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) over 27 months at a single centre and performed by a single surgeon. Patient imaging and surgical planning software were used to manufacture a 3D-printed patient-specific MIS TLIF kit for each patient consisting of a 1:1 scale spine BioModel, stereotactic K-wire guide, osteotomy guide, and retractors. Pre-selected pedicle screws, rods, and cages were sourced and supplied with the patient-specific kit. Additional implants were available on-shelf to address a size discrepancy between the kit implant and intraoperative measurements. Each BioModel was used pre-operatively for surgical planning, patient consent and education. The BioModel was sterilised for intraoperative reference and navigation purposes. Efficiency measures included operating time (153 ± 44 min), sterile tray usage (14 ± 3), fluoroscopy screening time (57.2 ± 23.7 s), operative waste (19 ± 8 L contaminated, 116 ± 30 L uncontaminated), and median hospital stay (4 days). The pre-selected kit implants exactly matched intraoperative measurements for 597/639 pedicle screws, 249/258 rods, and 46/148 cages. Pedicle screw placement accuracy was 97.8% (625/639) on postoperative CT. Complications included one intraoperative dural tear, no blood products administered, and six reoperations. Our experience demonstrates a viable application of patient-specific 3D-printed solutions and provides a benchmark for studies of efficiency in spinal fusion surgery.<br /> (Copyright © 2019 Elsevier Ltd. All rights reserved.)
- Subjects :
- Adult
Female
Humans
Lumbar Vertebrae surgery
Male
Middle Aged
Operative Time
Precision Medicine methods
Reoperation
Treatment Outcome
Imaging, Three-Dimensional methods
Minimally Invasive Surgical Procedures methods
Models, Anatomic
Precision Medicine instrumentation
Spinal Fusion methods
Surgery, Computer-Assisted methods
Subjects
Details
- Language :
- English
- ISSN :
- 1532-2653
- Volume :
- 71
- Database :
- MEDLINE
- Journal :
- Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia
- Publication Type :
- Academic Journal
- Accession number :
- 31843436
- Full Text :
- https://doi.org/10.1016/j.jocn.2019.11.008