Preclinical Evaluation of Pulsed Field Ablation: Electrophysiological and Histological Assessment of Thoracic Vein Isolation.
- Source :
-
Circulation. Arrhythmia and electrophysiology [Circ Arrhythm Electrophysiol] 2019 Dec; Vol. 12 (12), pp. e007781. Date of Electronic Publication: 2019 Dec 12. - Publication Year :
- 2019
-
Abstract
- Background: Pulsed field ablation (PFA) is a uniquely tissue-selective, nonthermal cardiac ablation modality. Delivery parameters such as the electrical waveform composition and device design are critical to PFA's efficacy and safety, particularly tissue specificity. In a series of preclinical studies, we sought to examine the electrophysiological and histological effects of PFA and compare the safety and feasibility of durable pulmonary vein and superior vena cava (SVC) isolation between radiofrequency ablation and PFA waveforms.<br />Methods: A femoral venous approach was used to gain right and left atrial access under general anesthesia in healthy swine. Baseline potentials in right superior pulmonary and inferior common vein and in SVC were assessed. Bipolar PFA was performed with monophasic (PFA <subscript>Mono</subscript> ) and biphasic (PFA <subscript>Bi</subscript> ) waveforms in 7 and 7 swine sequentially and irrigated radiofrequency ablation in 3 swine. Vein potentials were then assessed acutely, and at ≈10 weeks; histology was obtained.<br />Results: All targeted veins (n=46) were successfully isolated on the first attempt in all cohorts. The PFA <subscript>Bi</subscript> waveform induced significantly less skeletal muscle engagement. Pulmonary vein isolation durability was assessed in 28 veins: including the SVC, durability was significantly higher in the PFA <subscript>Bi</subscript> group (18/18 PFA <subscript>Bi</subscript> , 10/18 PFA <subscript>Mono</subscript> , 3/6 radiofrequency, P =0.002). Transmurality rates were similar across groups with evidence of nerve damage only with radiofrequency. Pulmonary vein narrowing was noted only in the radiofrequency cohort. The phrenic nerve was spared in all cohorts but at the expense of incomplete SVC encirclement with radiofrequency.<br />Conclusions: In this chronic porcine study, PFA-based pulmonary vein and SVC isolation were safe and efficacious with demonstrable sparing of nerves and venous tissue. This preclinical study provided the scientific basis for the first-in-human endocardial PFA studies.
- Subjects :
- Action Potentials
Animals
Catheter Ablation adverse effects
Female
Pulmonary Veins pathology
Pulmonary Veins physiopathology
Sus scrofa
Vena Cava, Superior pathology
Vena Cava, Superior physiopathology
Catheter Ablation methods
Pulmonary Veins surgery
Thorax blood supply
Vena Cava, Superior surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1941-3084
- Volume :
- 12
- Issue :
- 12
- Database :
- MEDLINE
- Journal :
- Circulation. Arrhythmia and electrophysiology
- Publication Type :
- Academic Journal
- Accession number :
- 31826647
- Full Text :
- https://doi.org/10.1161/CIRCEP.119.007781