Measurement Reliability and Diagnostic Accuracy of Virtual Monoenergetic Dual-Energy CT in Patients with Colorectal Liver Metastases.
- Source :
-
Academic radiology [Acad Radiol] 2020 Jul; Vol. 27 (7), pp. e168-e175. Date of Electronic Publication: 2019 Nov 11. - Publication Year :
- 2020
-
Abstract
- Rationale and Objectives: To compare dual-energy CT virtual monoenergetic images (VMI) and standard reconstructions for reliability of quantitative size measurements and diagnostic accuracy for the detection of colorectal liver metastases (CRLM).<br />Materials and Methods: We retrospectively included 98 patients (mean age, 61.1±11.5 years) with colorectal cancer, of whom 49 subjects had CRLM. All patients underwent a portal-venous phase dual-energy CT examination. Standard linearly-blended reformats and 40-keV VMI were reconstructed. For both reconstruction techniques, two blinded readers performed measurements of CRLM twice in a preset sequence. Three additional radiologists independently assessed all liver lesions in terms of dignity (benign vs. malignant). Sensitivity, specificity and diagnostic accuracy were calculated on a per-patient basis using MRI as reference standard. Readers scored the suitability for metric measurements and their diagnostic confidence using 5-point Likert scales. Inter-rater agreement was evaluated using intraclass correlation coefficient (ICC).<br />Results: Inter-rater agreement for lesion size measurements was higher for 40-keV VMI (ICC, 0.88) compared to standard linearly-blended series (ICC, 0.80). Sensitivity and diagnostic accuracy for the detection of CRLM were significantly higher for VMI at 40-keV compared to standard reconstructions (90.6% vs. 80.6%, and 89.1% vs. 81.3%; p < 0.001). Reader scores indicated that 40-keV VMI were more suitable for metric lesion measurements and provided greater diagnostic confidence compared to standard reformats (median, 5 vs. 3, and 5 vs. 4; both p < 0.001).<br />Conclusion: Low-keV VMI reconstructions improve reliability of quantitative size measurements and diagnostic accuracy for the assessment of CRLM compared to standard linearly-blended images.<br /> (Copyright © 2019. Published by Elsevier Inc.)
- Subjects :
- Aged
Humans
Middle Aged
Radiographic Image Interpretation, Computer-Assisted
Reproducibility of Results
Retrospective Studies
Signal-To-Noise Ratio
Tomography, X-Ray Computed
Colorectal Neoplasms diagnostic imaging
Liver Neoplasms diagnostic imaging
Radiography, Dual-Energy Scanned Projection
Subjects
Details
- Language :
- English
- ISSN :
- 1878-4046
- Volume :
- 27
- Issue :
- 7
- Database :
- MEDLINE
- Journal :
- Academic radiology
- Publication Type :
- Academic Journal
- Accession number :
- 31727567
- Full Text :
- https://doi.org/10.1016/j.acra.2019.09.020