Background: Postbariatric hypoglycemia (PBH) can threaten safety and reduce quality of life. Current therapies are incompletely effective.<br />Methods: Patients with PBH were enrolled in a double-blind, placebo-controlled, crossover trial to evaluate a closed-loop glucose-responsive automated glucagon delivery system designed to reduce severe hypoglycemia. A hypoglycemia detection and mitigation algorithm was embedded in the artificial pancreas system connected to a continuous glucose monitor (CGM, Dexcom) driving a patch infusion pump (Insulet) filled with liquid investigational glucagon (Xeris) or placebo (vehicle). Sensor/plasma glucose responses to mixed meal were assessed during 2 study visits. The system delivered up to 2 doses of study drug (300/150 μg glucagon or equal-volume vehicle) if triggered by the algorithm. Rescue dextrose was given for plasma glucose <55 mg/dL or neuroglycopenia.<br />Results: Twelve participants (11 females/1 male, age 52 ± 2, 8 ± 1 years postsurgery, mean ± SEM) completed all visits. Predictive hypoglycemia alerts prompted automated drug delivery postmeal, when sensor glucose was 114 ± 7 vs 121 ± 5 mg/dL (P = .39). Seven participants required rescue glucose after vehicle but not glucagon (P = .008). Five participants had severe hypoglycemia (<55 mg/dL) after vehicle but not glucagon (P = .03). Nadir plasma glucose was higher with glucagon vs vehicle (67 ± 3 vs 59 ± 2 mg/dL, P = .004). Plasma glucagon rose after glucagon delivery (1231 ± 187 vs 16 ± 1 pg/mL at 30 minutes, P = .001). No rebound hyperglycemia occurred. Transient infusion site discomfort was reported with both glucagon (n = 11/12) and vehicle (n = 10/12). No other adverse events were observed.<br />Conclusion: A CGM-guided closed-loop rescue system can detect imminent hypoglycemia and deliver glucagon, reducing severe hypoglycemia in PBH.<br />Clinical Trials Registration: NCT03255629.<br /> (© Endocrine Society 2019. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.)

Details

Language :
English
ISSN :
1945-7197
Volume :
105
Issue :
4
Database :
MEDLINE
Journal :
The Journal of clinical endocrinology and metabolism
Publication Type :
Academic Journal
Accession number :
31714583
Full Text :
https://doi.org/10.1210/clinem/dgz197