Back to Search
Start Over
A European inter-laboratory trial to evaluate the performance of three serological methods for diagnosis of Mycoplasma bovis infection in cattle using latent class analysis.
- Source :
-
BMC veterinary research [BMC Vet Res] 2019 Oct 25; Vol. 15 (1), pp. 369. Date of Electronic Publication: 2019 Oct 25. - Publication Year :
- 2019
-
Abstract
- Background: Mycoplasma bovis (M. bovis) is an emerging bovine pathogen, leading to significant economic losses in the livestock industry worldwide. Infection can result in a variety of clinical signs, such as arthritis, pneumonia, mastitis and keratoconjunctivitis, none of which are M. bovis-specific. Laboratory diagnosis is therefore important. Serological tests to detect M. bovis antibodies is considered an effective indicator of infection in a herd and often used as a herd test. Combined with clinical judgement, it can also be used to implement control strategies and/or to estimate the disease prevalence within a country. However, due to lack of harmonisation of approaches to testing, and serological tests used by different laboratories, comparisons of prevalence data between countries is often difficult. A network of researchers from six European countries designed and participated in an inter-laboratory trial, with the aim of evaluating the sensitivity (Se) and specificity (Sp) of two commercially available ELISA tests (ID Screen® ELISA (IDvet) and BIO K302 ELISA (BIO-X Diagnostics)) for diagnosis of M. bovis infection. Each laboratory received a blinded panel of bovine sera and tested independently, according to manufacturer's instructions. Western blot analyses (WB) performed by one of the participating laboratories was used as a third diagnostic test in the statistical evaluation of Se and Sp values using latent class analysis.<br />Results: The Se of WB, the ID Screen® ELISA and the BIO K302 ELISA were determined to be 91.8, 93.5 and 49.1% respectively, and corresponding Sp of the three tests were 99.6, 98.6 and 89.6%, respectively.<br />Conclusions: The present study is, to our knowledge, the first to present an inter-laboratory comparison of the BIO K302 ELISA and the ID Screen® ELISA. Based on our results, the ID Screen® ELISA showed high consistency with WB and performed with higher precision and accuracy than the BIO K302 ELISA.
- Subjects :
- Animals
Blotting, Western veterinary
Cattle
Cattle Diseases blood
Enzyme-Linked Immunosorbent Assay methods
Latent Class Analysis
Mycoplasma Infections blood
Mycoplasma Infections diagnosis
Mycoplasma bovis immunology
Sensitivity and Specificity
Serologic Tests veterinary
Cattle Diseases diagnosis
Enzyme-Linked Immunosorbent Assay veterinary
Mycoplasma Infections veterinary
Subjects
Details
- Language :
- English
- ISSN :
- 1746-6148
- Volume :
- 15
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- BMC veterinary research
- Publication Type :
- Academic Journal
- Accession number :
- 31653217
- Full Text :
- https://doi.org/10.1186/s12917-019-2117-0