Implications of hydrodynamic testing to guide sizing of self-expanding transcatheter heart valves for valve-in-valve procedures.
- Source :
-
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2020 Sep 01; Vol. 96 (3), pp. E332-E340. Date of Electronic Publication: 2019 Oct 24. - Publication Year :
- 2020
-
Abstract
- Aims: The commonly used valve-in-valve (VIV) app recommends sizing based on dimensions of both the transcatheter heart valve (THV) and bioprosthetic surgical valve. The implications of hydrodynamic testing to guide VIV sizing are poorly understood. This bench study assessed the hydrodynamic performance of different sizes of self-expanding supra-annular THVs in three different surgical aortic bioprostheses at different implantation depths.<br />Methods: A small versus medium ACURATE neo (ACn), and a 26 mm versus 29 mm Evolut R were assessed after VIV implantation in 25 mm Mitroflow, Mosaic, and Magna Ease aortic surgical bioprostheses, at three implantation depths (+2 mm, -2 mm, and -6 mm).<br />Results: The medium-sized ACn had lower gradients compared to the small ACn when the THV was implanted high (+2 mm, or -2 mm). The 29 mm Evolut R had lower gradients compared to a 26 mm Evolut R for all implantation depths, except for a depth of -2 mm in the 25 mm Mitroflow. The medium ACn and 29 mm Evolut R had larger effective orifice areas compared to the small ACn and 26 mm Evolut R, respectively. Both Evolut R sizes had acceptable regurgitant fractions (<15%), while both ACn sizes were above the acceptable performance criteria (>15%), at all implantation depths.<br />Conclusions: Use of a larger self-expanding THV was associated with superior hydrodynamic performance if the THV was implanted high. Hydrodynamic testing can provide additional information to the VIV app to help guide VIV sizing.<br /> (© 2019 Wiley Periodicals, Inc.)
- Subjects :
- Cardiac Catheterization adverse effects
Heart Valve Diseases physiopathology
Heart Valve Prosthesis Implantation adverse effects
Heart Valves physiopathology
Humans
Hydrodynamics
Materials Testing
Prosthesis Design
Time Factors
Transcatheter Aortic Valve Replacement adverse effects
Bioprosthesis
Cardiac Catheterization instrumentation
Heart Valve Diseases surgery
Heart Valve Prosthesis
Heart Valve Prosthesis Implantation instrumentation
Heart Valves surgery
Transcatheter Aortic Valve Replacement instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1522-726X
- Volume :
- 96
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
- Publication Type :
- Academic Journal
- Accession number :
- 31647178
- Full Text :
- https://doi.org/10.1002/ccd.28537