Comparison of outcomes in infected cardiovascular implantable electronic devices between complete, partial, and failed lead removal: an ESC-EHRA-EORP ELECTRa (European Lead Extraction ConTrolled) registry.
Comparison of outcomes in infected cardiovascular implantable electronic devices between complete, partial, and failed lead removal: an ESC-EHRA-EORP ELECTRa (European Lead Extraction ConTrolled) registry.
- Source :
-
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2019 Dec 01; Vol. 21 (12), pp. 1876-1889. - Publication Year :
- 2019
-
Abstract
- Aims: The present study sought to determine predictors for success and outcomes of patients who underwent cardiac implantable electronic devices (CIED) extraction indicated for systemic or local CIED related infection in particular where complete lead removal could not be achieved.<br />Methods and Results: ESC-EORP ELECTRa (European Lead Extraction ConTRolled Registry) is a European prospective lead extraction registry. Out of the total cohort, 1865/3510 (52.5%) patients underwent removal due to CIED related infection. Predictors and outcomes of failure were analysed. Complete removal was achieved in 1743 (93.5%) patients, partial (<4 cm of lead left) in 88 (4.7%), and failed (>4 cm of lead left) in 32 (1.8%) patients. Removal success was unrelated to type of CIED infection (pocket or systemic). Predictors for failure were older leads and older patients [odds ratio (OR) 1.14 (1.08-1.19), P < 0.0001 and OR 2.68 (1.22-5.91), P = 0.0146, respectively]. In analysis by lead, predictors for failure were: pacemaker vs. defibrillator removal and failure to engage the locking stylet all the way to the tip [OR 0.20 (0.04-0.95), P = 0.03 and OR 0.32 (0.13-0.74), P = 0.008, respectively]. Significantly higher complication rates were noted in the failure group (40.6% vs. 15.9 for partial and 8.7% for success groups, P < 0.0001). Failure to remove a lead was a strong predictor for in hospital mortality [hazard ratio of 2.05 (1.01-4.16), P = 0.046].<br />Conclusion: A total of 6.5% of infected CIED patients failed attempted extraction. Only were >4 cm of lead remained resulted in higher procedural complications and mortality rates.<br /> (Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2019. For permissions, please email: journals.permissions@oup.com.)
- Subjects :
- Age Factors
Aged
Anti-Bacterial Agents therapeutic use
Electrodes, Implanted
Europe
Female
Humans
Male
Middle Aged
Registries
Time Factors
Treatment Failure
Treatment Outcome
Cardiac Resynchronization Therapy Devices
Defibrillators, Implantable
Device Removal statistics & numerical data
Pacemaker, Artificial
Prosthesis-Related Infections therapy
Subjects
Details
- Language :
- English
- ISSN :
- 1532-2092
- Volume :
- 21
- Issue :
- 12
- Database :
- MEDLINE
- Journal :
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 31625553
- Full Text :
- https://doi.org/10.1093/europace/euz269