Back to Search
Start Over
Mid-term outcome in patients with bicuspid aortic valve stenosis following transcatheter aortic valve replacement with a current generation device: A multicenter study.
- Source :
-
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2020 May 01; Vol. 95 (6), pp. 1186-1192. Date of Electronic Publication: 2019 Sep 04. - Publication Year :
- 2020
-
Abstract
- Objectives: To perform clinical and echocardiographic follow-up beyond 1 year in consecutive patients with severe bicuspid aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) with a current generation balloon-expandable valve.<br />Background: Treatment of bicuspid aortic valve disease with TAVR remains controversial and late follow-up data is still scarce.<br />Methods: We collected baseline characteristics, procedural data, 30-day and mid-term clinical follow-up findings from six centers in Europe and Canada from patients with bicuspid AS treated with TAVR using the SAPIEN 3 valve.<br />Results: Seventy-nine patients underwent TAVR. Mean age was 76 ± 9 years; median STS risk score for mortality was 3.8% (interquartile range 2.3-5.5%). Median follow-up was 390 days (interquartile range 138-739 days). Device success was achieved in 95% of patients. Postimplantation mean aortic gradient decreased from 50.2 ± 16.2 to 8.8 ± 4.4 mmHg and no patient had more than mild aortic regurgitation. At last follow-up, there was persistent good valve performance. At 30 days and 1 year, the rates of all-cause mortality were 3.8 and 7.7%, stroke 1.2 and 1.2%, and the rate of new pacemakers 18 and 18%.<br />Conclusions: Our data confirm that treating patients with stenotic bicuspid aortic valves is safe, effective, and has favorable valve performance over time.<br /> (© 2019 Wiley Periodicals, Inc.)
- Subjects :
- Aged
Aged, 80 and over
Aortic Valve Insufficiency etiology
Aortic Valve Insufficiency physiopathology
Aortic Valve Stenosis diagnostic imaging
Aortic Valve Stenosis mortality
Aortic Valve Stenosis physiopathology
Bicuspid Aortic Valve Disease diagnostic imaging
Bicuspid Aortic Valve Disease mortality
Bicuspid Aortic Valve Disease physiopathology
Canada
Europe
Female
Hemodynamics
Humans
Male
Recovery of Function
Risk Factors
Time Factors
Transcatheter Aortic Valve Replacement adverse effects
Transcatheter Aortic Valve Replacement mortality
Treatment Outcome
Aortic Valve Stenosis surgery
Bicuspid Aortic Valve Disease surgery
Heart Valve Prosthesis
Transcatheter Aortic Valve Replacement instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1522-726X
- Volume :
- 95
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
- Publication Type :
- Academic Journal
- Accession number :
- 31483555
- Full Text :
- https://doi.org/10.1002/ccd.28475