Back to Search
Start Over
Meta-Analysis Comparing Transcatheter Aortic Valve Implantation With Balloon Versus Self-Expandable Valves.
- Source :
-
The American journal of cardiology [Am J Cardiol] 2019 Oct 15; Vol. 124 (8), pp. 1252-1256. Date of Electronic Publication: 2019 Jul 29. - Publication Year :
- 2019
-
Abstract
- Two transcatheter aortic valve systems are currently in use in the United States; balloon-expandable valves (BEV) and the self-expanding valve (SEV). However, comparative data outcomes between the 2 systems are limited, as only one randomized trial (RCT) performed a head-to-head comparison between BEVs and SEVs. However, there are several RCTs comparing BEV or SEV to surgical valve replacement. In this analysis, we used Bayesian network meta-analysis techniques to compare BEVs and SEVs. The primary outcome was all-cause mortality at maximum follow-up. Secondary outcomes were cardiovascular mortality, stroke, pacemaker implantation, reintervention, heart failure hospitalization, and moderate-severe paravalvular leak (PVL.). Eight RCTs with 8,095 patients were included. With the exception of less pacemaker implantation in BEV versus SEV (odds ratio [OR] 0.29, 95% confidence interval [CI] 0.11 to 0.77, I <superscript>2</superscript> = 51%), there was no difference between BEV and SEV in 30-day outcomes. During long-term follow-up (mean 3 ± 2 years); there was no difference between BEV and SEV in all-cause mortality (hazard ratio [HR] 1.1, 95% CI 0.87 to 1.5, I <superscript>2</superscript> = 19.6%), cardiovascular mortality (HR 1.1, 95% CI 0.73 to 1.6, I <superscript>2</superscript> = 18.5%), stroke (HR 1.3, 95% CI 0.73 to 2.1, I <superscript>2</superscript> = 16.9%), hospitalization (HR 0.87, 95% CI 0.41 to 1.6, I <superscript>2</superscript> = 62%), and reintervention (HR 0.68, 95% CI 0.2 to 2.3, I <superscript>2</superscript> = 62%). New pacemaker implantation and PVL were significantly less in BEV group (HR 0.45, 95% CI 0.24 to 0.80, I <superscript>2</superscript> = 38.2%), and (HR 0.03, 95% CI 0.0004 to 0.28, I <superscript>2</superscript> = 79%), respectively. In conclusion, similar outcomes were seen following transcatheter aortic valve implantation with BEV and SEV with the exception of higher rates of pacemaker implantation and PVL in SEV group.<br /> (Copyright © 2019 Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1879-1913
- Volume :
- 124
- Issue :
- 8
- Database :
- MEDLINE
- Journal :
- The American journal of cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 31470973
- Full Text :
- https://doi.org/10.1016/j.amjcard.2019.07.028