Back to Search Start Over

Use of 65 cm large caliber Dryseal sheaths to facilitate delivery of the Edwards SAPIEN valve to dysfunctional right ventricular outflow tracts.

Authors :
Kenny D
Morgan GJ
Murphy M
AlAlwi K
Giugno L
Zablah J
Carminati M
Walsh K
Source :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2019 Sep 01; Vol. 94 (3), pp. 409-413. Date of Electronic Publication: 2019 Aug 13.
Publication Year :
2019

Abstract

Background: The Edwards SAPIEN valve and its delivery system may complicate transit through the right heart during transcatheter pulmonary valve replacement (tPVR). We report our early experience using a large diameter, 65 cm delivery sheath to facilitate delivery of the SAPIEN valve to the right ventricular outflow tract (RVOT).<br />Methods: Retrospective analysis of all patients from three large congenital heart centers undergoing tPVR with the Edwards SAPIEN valve delivered with the 65 cm Gore Dryseal Sheath.<br />Results: Over a 12 month period, 30 patients (17 female) with median age 17.5 years (range 8-72) underwent attempted tPVR with the SAPIEN valve delivered using the 65 cm Dryseal sheath (20-26Fr). All procedures resulted in successful valve delivery to the target area. Twenty patients had a native RVOT. The most commonly used valve diameter was 29 mm (n = 15) with the majority of cases requiring a 26Fr Dryseal sheath (n = 20). One patient with severe RVOT stenosis underwent prestenting. Median procedure time was 100 min (59-225). No patient had increase in tricuspid valve regurgitation as a consequence of valve delivery. One patient required a synchronous cardioversion for intraprocedural VT and another required ECMO postprocedure due to severe pre-existing left ventricular dysfunction. On median follow-up of 5 months, all patients had mild or less pulmonary regurgitation. Median peak Doppler velocity across the pulmonary valve was 2.2 m/s (1.7-4). There were no clinically relevant complications relating to vascular access.<br />Conclusions: Using 65 cm Dryseal sheaths facilitates delivery of SAPIEN valves in patients with dysfunctional RVOTs.<br /> (© 2019 Wiley Periodicals, Inc.)

Details

Language :
English
ISSN :
1522-726X
Volume :
94
Issue :
3
Database :
MEDLINE
Journal :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Publication Type :
Academic Journal
Accession number :
31408262
Full Text :
https://doi.org/10.1002/ccd.28409