Back to Search
Start Over
False-positive aortography following blunt chest trauma: case report.
- Source :
-
Cardiovascular and interventional radiology [Cardiovasc Intervent Radiol] 1988 Jun; Vol. 11 (3), pp. 132-5. - Publication Year :
- 1988
-
Abstract
- We describe a patient in whom thoracic aortography performed following blunt chest trauma revealed what appeared to be a traumatic tear of the proximal descending aorta. As the patient initially refused surgery, aortography was repeated 18 days later, confirming these findings. At thoracic aortotomy the aorta appeared normal; there was no hematoma or tear. We believe this to be the first reported case of false-positive aortography following blunt chest trauma (see Note added in proof).
Details
- Language :
- English
- ISSN :
- 0174-1551
- Volume :
- 11
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Cardiovascular and interventional radiology
- Publication Type :
- Academic Journal
- Accession number :
- 3139293
- Full Text :
- https://doi.org/10.1007/BF02577102