Back to Search
Start Over
Institutional Variation in Quality of Cardiovascular Implantable Electronic Device Implantation: A Cohort Study.
- Source :
-
Annals of internal medicine [Ann Intern Med] 2019 Sep 03; Vol. 171 (5), pp. 309-317. Date of Electronic Publication: 2019 Jul 30. - Publication Year :
- 2019
-
Abstract
- Background: Cardiovascular implantable electronic devices (CIEDs) are associated with procedure-related complications, yet little is known about variation in complication rates among institutions that may suggest disparities in care quality.<br />Objective: To assess institutional variation in risk-standardized complication rates (RSCRs) for CIED.<br />Design: Cohort study.<br />Setting: 174 hospitals in Australia and New Zealand, 98 of which implanted at least 25 CIEDs during the study period.<br />Participants: 81 304 patients older than 18 years (mean, 74.7 years [SD, 12.4]; 37.9% female) who received a new CIED (65 711 permanent pacemakers [PPMs] and 15 593 implantable cardioverter-defibrillators [ICDs]) in 2010 to 2015.<br />Measurements: RSCRs and frequencies of major device-related complications during hospitalization or within 90 days of discharge.<br />Results: Of the cohort, 6664 patients (8.2%) had a major complication. Although complication rates were higher for ICDs than PPMs (10.04% vs. 7.76%), 76.5% of all complications were attributable to PPMs (5098 vs. 1566 for ICDs). Among hospitals that implanted at least 25 CIEDs, the median RSCR was 8.1%; however, rates varied from 5.3% to 14.3%, with 22 hospitals identified as having RSCRs that differed significantly from the national average. Similar variation was observed when RSCRs for PPM implantation (n = 96 hospitals) (median RSCR, 7.6% [range, 5.4% to 12.9%]) were considered separately from those for ICD placement (n = 68 hospitals) (median RSCR, 9.7% [range, 6.2% to 16.9%]) and persisted when only elective procedures were assessed (n = 88 hospitals) (median RSCR, 7.4% [range, 4.7% to 13.0%]).<br />Limitation: Possible unmeasured confounding from the use of administrative data.<br />Conclusion: CIED complications are common and vary among hospitals, suggesting institutional variation in CIED care quality. Concerted clinical and policy interventions are needed to address CIED-related complications. These efforts should preferentially target PPMs, because most CIED complications are attributable to these devices.<br />Primary Funding Source: The Hospitals Contribution Fund Research Foundation.
Details
- Language :
- English
- ISSN :
- 1539-3704
- Volume :
- 171
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Annals of internal medicine
- Publication Type :
- Academic Journal
- Accession number :
- 31357210
- Full Text :
- https://doi.org/10.7326/M18-2810