Back to Search Start Over

Dexmedetomidine vs propofol as sedation for implantation of neurostimulators: A single-center single-blinded randomized controlled trial.

Authors :
Ter Bruggen FFJA
Ceuppens C
Leliveld L
Stronks DL
Huygen FJPM
Source :
Acta anaesthesiologica Scandinavica [Acta Anaesthesiol Scand] 2019 Nov; Vol. 63 (10), pp. 1321-1329. Date of Electronic Publication: 2019 Aug 09.
Publication Year :
2019

Abstract

Background: During the lead implantation of most spinal cord neurostimulators, the patient has to be comfortable and without pain. However, the patient is expected to provide feedback during electrical mapping. Titrating sedatives and analgesics for this double goal can be challenging. In comparison with our standard sedative agent propofol, the pharmacological profile of dexmedetomidine is more conducive to produce arousable sedation. The latter, however, is associated with hemodynamic side effects. We investigated whether dexmedetomidine is preferable over propofol during neurostimulator implantation.<br />Methods: This single-center single-blinded randomized controlled trial included 72 patients with an indication for a neurostimulator, randomized to sedation with either propofol (0.5 mg/kg for 10 minutes, followed by 2.0 mg/kg/h) or dexmedetomidine (1 μg/kg for 10 minutes, followed by 0.6 μg/kg/h). The primary outcome was patient satisfaction with the sedation. The secondary outcomes were patient's and operator's comfort, number of titration adjustments, standard intraoperative hemodynamic and respiratory parameters and side effects.<br />Results: Data of 69 patients (dexmedetomidine n = 35; propofol n = 34) were analyzed. Those receiving dexmedetomidine were more satisfied with the sedation than those receiving propofol; i.e. with sedation delivery (median 100.0 vs 83.3, P < .01), procedural recall (median 95.8 vs 83.3, P = .03), and sedation side effects (median 90.0 vs 83.3, P = .01). Fewer changes in the dexmedetomidine titration were necessary to maintain arousable sedation. Over time, mean arterial pressure and heart rate were significantly lower in the dexmedetomidine group. Hemodynamic side effects were comparable across groups.<br />Conclusions: Dexmedetomidine sedation resulted in higher patient satisfaction and allowed for better arousable sedation than sedation with propofol. Although differences in hemodynamic parameters were found between the groups, these differences were not regarded as clinically relevant.<br /> (© 2019 Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.)

Details

Language :
English
ISSN :
1399-6576
Volume :
63
Issue :
10
Database :
MEDLINE
Journal :
Acta anaesthesiologica Scandinavica
Publication Type :
Academic Journal
Accession number :
31321763
Full Text :
https://doi.org/10.1111/aas.13452