Back to Search Start Over

Incidence, predictors and cerebrovascular consequences of leaflet thrombosis after transcatheter aortic valve implantation: a systematic review and meta-analysis.

Authors :
D'Ascenzo F
Salizzoni S
Saglietto A
Cortese M
Latib A
Franzone A
Barbanti M
Nietlispach F
Holy EW
Burriesci G
De Paoli A
Fonio P
Atzeni F
Moretti C
Perl L
D'Amico M
Rinaldi M
Conrotto F
Source :
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery [Eur J Cardiothorac Surg] 2019 Sep 01; Vol. 56 (3), pp. 488-494.
Publication Year :
2019

Abstract

Objectives: We examined the incidence, the impact of subsequent cerebrovascular events and the clinical or procedural predictors of leaflet thrombosis (LT) in patients undergoing transcatheter aortic valve implantation (TAVI).<br />Methods: MEDLINE/PubMed was systematically screened for studies reporting on LT in TAVI patients. Incidence [both clinical and subclinical, i.e. detected with computed tomography (CT)] of LT was the primary end point of the study. Predictors of LT evaluated at multivariable analysis and impact of LT on stroke were the secondary ones.<br />Results: Eighteen studies encompassing 11 124 patients evaluating incidence of LT were included. Pooled incidence of LT was 0.43% per month [5.16% per year, 95% confidence interval (CI) 0.21-0.72, I2 = 98%]. Pooled incidence of subclinical LT was 1.36% per month (16.32% per year, 95% CI 0.71-2.19, I2 = 94%). Clinical LT was less frequent (0.04% per month, 0.48% per year, 95% CI 0.00-0.19, I2 = 93%). LT increased the risk of stroke [odds ratio (OR) 4.21, 95% CI 1.27-13.98], and was more frequent in patients with a valve diameter of 28-mm (OR 2.89: 1.55-5.8), for balloon-expandable (OR 8: 2.1-9.7) or after valve-in-valve procedures (OR 17.1: 3.1-84.9). Oral anticoagulation therapy reduced the risk of LT (OR 0.43, 95% CI: 0.22-0.84, I2 = 64%), as well as the mean transvalvular gradient.<br />Conclusions: LT represents an infrequent event after TAVI, despite increasing risk of stroke. Given its full reversal with warfarin, in high-risk patients (those with valve-in-valve procedures, balloon expandable or large-sized devices), a protocol which includes a control CT appears reasonable.<br /> (© The Author(s) 2019. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.)

Details

Language :
English
ISSN :
1873-734X
Volume :
56
Issue :
3
Database :
MEDLINE
Journal :
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
Publication Type :
Academic Journal
Accession number :
31321408
Full Text :
https://doi.org/10.1093/ejcts/ezz099