Back to Search Start Over

Automated macrophage counting in DLBCL tissue samples: a ROF filter based approach.

Authors :
Wagner M
Hänsel R
Reinke S
Richter J
Altenbuchinger M
Braumann UD
Spang R
Löffler M
Klapper W
Source :
Biological procedures online [Biol Proced Online] 2019 Jul 01; Vol. 21, pp. 13. Date of Electronic Publication: 2019 Jul 01 (Print Publication: 2019).
Publication Year :
2019

Abstract

Background: For analysis of the tumor microenvironment in diffuse large B-cell lymphoma (DLBCL) tissue samples, it is desirable to obtain information about counts and distribution of different macrophage subtypes. Until now, macrophage counts are mostly inferred from gene expression analysis of whole tissue sections, providing only indirect information. Direct analysis of immunohistochemically (IHC) fluorescence stained tissue samples is confronted with several difficulties, e.g. high variability of shape and size of target macrophages and strongly inhomogeneous intensity of staining. Consequently, application of commercial software is largely restricted to very rough analysis modes, and most macrophage counts are still obtained by manual counting in microarrays or high power fields, thus failing to represent the heterogeneity of tumor microenvironment adequately.<br />Methods: We describe a Rudin-Osher-Fatemi (ROF) filter based segmentation approach for whole tissue samples, combining floating intensity thresholding and rule-based feature detection. Method is validated against manual counts and compared with two commercial software kits (Tissue Studio 64, Definiens AG, and Halo, Indica Labs) and a straightforward machine-learning approach in a set of 50 test images. Further, the novel method and both commercial packages are applied to a set of 44 whole tissue sections. Outputs are compared with gene expression data available for the same tissue samples. Finally, the ROF based method is applied to 44 expert-specified tumor subregions for testing selection and subsampling strategies.<br />Results: Among all tested methods, the novel approach is best correlated with manual count (0.9297). Automated detection of evaluation subregions proved to be fully reliable. Comparison with gene expression data obtained for the same tissue samples reveals only moderate to low correlation levels. Subsampling within tumor subregions is possible with results almost identical to full sampling. Mean macrophage size in tumor subregions is 152.5±111.3 μ m <superscript>2</superscript> .<br />Conclusions: ROF based approach is successfully applied to detection of IHC stained macrophages in DLBCL tissue samples. The method competes well with existing commercial software kits. In difference to them, it is fully automated, externally repeatable, independent on training data and completely documented. Comparison with gene expression data indicates that image morphometry constitutes an independent source of information about antibody-polarized macrophage occurence and distribution.<br />Competing Interests: Competing interestsThe authors declare that they have no competing interests.

Details

Language :
English
ISSN :
1480-9222
Volume :
21
Database :
MEDLINE
Journal :
Biological procedures online
Publication Type :
Academic Journal
Accession number :
31303867
Full Text :
https://doi.org/10.1186/s12575-019-0098-9