Back to Search
Start Over
Low-dose imaging technique (LITE) MRI: initial experience in breast imaging.
- Source :
-
The British journal of radiology [Br J Radiol] 2019 Nov; Vol. 92 (1103), pp. 20190302. Date of Electronic Publication: 2019 Jul 11. - Publication Year :
- 2019
-
Abstract
- Objectives: To compare a low-dose dynamic contrast-enhanced breast MRI protocol (LITE MRI) to standard-dosage using a dual-dose injection technique.<br />Methods: 8 females with a total of 10 lesions with imaging features compatible with fibroadenoma were imaged using a dual-dose dynamic contrast-enhanced-MRI (DCE-MRI) technique. After pre-contrast scans, 15% of a standard dose of contrast was administered; approximately 10 min later, the remaining 85% of the standard dose was administered. Enhancement kinetic parameters, conspicuity and signal-to-noise ratio were measured quantitatively.<br />Results: One lesion showed no enhancement in either DCE series. All nine of the enhancing lesions were visualized in both the low-dose and standard-dose images. While the (low-to-standard) ratio of contrast doses was roughly 0.18, this did not match the ratios of kinetic parameters. Lesion conspicuity and enhancement rate were both higher in the low-dose images, with (low-to-standard) ratios 1.5 ± 0.1 and 1.2 ± 0.4, respectively. The upper limit of enhancement (ratio 0.3 ± 0.1) and signal-to-noise ratio (ratio 0.5 ± 0.1) were higher in the standard-dose images, but less than expected based on the ratio of the doses.<br />Conclusions: This preliminary study demonstrates that LITE MRI has the potential to match standard DCE-MRI in the detection of enhancing lesions. Additionally, LITE MRI may enhance sensitivity to contrast media dynamics.<br />Advances in Knowledge: Lower doses of MRI contrast media may be equally effective in the detection of breast lesions, and increase sensitivity to contrast media dynamics. LITE MRI may help increase screening compliance and long-term patient safety.
- Subjects :
- Adolescent
Adult
Contrast Media administration & dosage
Contrast Media pharmacokinetics
Dose-Response Relationship, Drug
Female
Gadolinium administration & dosage
Gadolinium pharmacokinetics
Humans
Magnetic Resonance Imaging methods
Middle Aged
Signal-To-Noise Ratio
Young Adult
Breast Neoplasms diagnosis
Fibroadenoma diagnosis
Subjects
Details
- Language :
- English
- ISSN :
- 1748-880X
- Volume :
- 92
- Issue :
- 1103
- Database :
- MEDLINE
- Journal :
- The British journal of radiology
- Publication Type :
- Academic Journal
- Accession number :
- 31271535
- Full Text :
- https://doi.org/10.1259/bjr.20190302