Back to Search
Start Over
A modified zeolite/iron oxide composite as a sorbent for magnetic dispersive solid-phase extraction for the preconcentration of nonsteroidal anti-inflammatory drugs in water and urine samples.
- Source :
-
Journal of chromatography. A [J Chromatogr A] 2019 Oct 11; Vol. 1603, pp. 33-43. Date of Electronic Publication: 2019 Jun 17. - Publication Year :
- 2019
-
Abstract
- This study is the first to use a new ZSM-5 zeolite-based composite decorated with iron oxide magnetic nanoparticles and modified with hexadecyltrimethylammonium bromide surfactant (i.e., HDTMA-ZSM-5/Fe <subscript>2</subscript> O <subscript>3</subscript> ) as an efficient sorbent for magnetic dispersive solid-phase extraction (MDSPE) of nonsteroidal anti-inflammatory drugs in water and urine samples with subsequent measurement by liquid chromatography diode array detection. Experimental factors affecting MDSPE were optimized using a multivariate optimization strategy. The optimum experimental conditions were: amount of sorbent, 40 mg; sample pH, 2.2; NaCl concentration, 2.5%; extraction time, 2 min; eluent solvent, methanol; eluent solvent volume, 424 μL; and elution time, 2 min. The linearity of the method was studied from 3.3 to 400 μg L <superscript>-1</superscript> (N = 8) for ketoprofen, from 1.7 to 400 μg L <superscript>-1</superscript> (N = 8) for felbinac, from 6.6 to 400 μg L <superscript>-1</superscript> (N = 7) for diclofenac and from 9.9 to 400 μg L <superscript>-1</superscript> (N = 6) for ibuprofen. Method repeatability was evaluated at 10 and 200 μg L <superscript>-1</superscript> spiking levels, obtaining coefficients of variation between 2 and 5% (n = 6). Limits of detection, determined empirically, were 1.0 μg L <superscript>-1</superscript> , 0.5 μg L <superscript>-1</superscript> , 2.0 μg L <superscript>-1</superscript> and 3.0 μg L <superscript>-1</superscript> for ketoprofen, felbinac, diclofenac and ibuprofen, respectively. Tap water, reservoir water, wastewater and five urine samples were selected to assess method applicability. Recovery values ranged between 86-107% and 80-112% for water and urine samples, respectively, showing negligible matrix effects. Finally, this method was employed to monitor ibuprofen excretion in real urine samples.<br /> (Copyright © 2019 Elsevier B.V. All rights reserved.)
- Subjects :
- Humans
Limit of Detection
Urinalysis
Wastewater chemistry
Anti-Inflammatory Agents, Non-Steroidal analysis
Anti-Inflammatory Agents, Non-Steroidal isolation & purification
Ferric Compounds chemistry
Magnetite Nanoparticles chemistry
Solid Phase Extraction methods
Water Pollutants, Chemical analysis
Water Pollutants, Chemical isolation & purification
Zeolites chemistry
Subjects
Details
- Language :
- English
- ISSN :
- 1873-3778
- Volume :
- 1603
- Database :
- MEDLINE
- Journal :
- Journal of chromatography. A
- Publication Type :
- Academic Journal
- Accession number :
- 31248585
- Full Text :
- https://doi.org/10.1016/j.chroma.2019.06.039