Back to Search Start Over

Monolithic CAD-CAM lithium disilicate versus monolithic CAD-CAM zirconia for single implant-supported posterior crowns using a digital workflow: A 3-year cross-sectional retrospective study.

Authors :
De Angelis P
Passarelli PC
Gasparini G
Boniello R
D'Amato G
De Angelis S
Source :
The Journal of prosthetic dentistry [J Prosthet Dent] 2020 Feb; Vol. 123 (2), pp. 252-256. Date of Electronic Publication: 2019 Jun 12.
Publication Year :
2020

Abstract

Statement of Problem: Dentistry has evolved significantly with the introduction of digital technologies and materials; however, clinical evidence for the performance of the complete digital workflow for single implant-supported posterior crowns is lacking.<br />Purpose: The purpose of this cross-sectional retrospective clinical study was to compare the clinical outcomes of 2 types of implant-supported crown used to replace a single missing posterior tooth in a completely digital workflow: transocclusal screw-retained monolithic lithium disilicate crowns versus transocclusal screw-retained monolithic zirconia crowns.<br />Material and Methods: A total of 38 participants who had been provided with dental implants and transocclusal screw-retained monolithic lithium disilicate or zirconia single crowns were evaluated in the study. Clinical and esthetic outcomes were recorded after a 3-year follow-up.<br />Results: Both groups had comparable clinical outcomes with a survival rate of 100%. In the lithium disilicate group, 89% of the participants were free of technical complications, and 95%, in the zirconia group. Only 1 patient experienced minor chipping affecting a lithium disilicate crown. All complications were considered minor and were easily resolved, and none of the participants required replacement of a crown. No biological complications were recorded in either group.<br />Conclusions: Within the limitations of this cross-sectional retrospective clinical study, monolithic lithium disilicate and zirconia screw-retained single crowns fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) and a fully digital workflow were found to be reliable and suitable clinical options for restoring a posterior missing tooth on a dental implant.<br /> (Copyright © 2019 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1097-6841
Volume :
123
Issue :
2
Database :
MEDLINE
Journal :
The Journal of prosthetic dentistry
Publication Type :
Academic Journal
Accession number :
31202552
Full Text :
https://doi.org/10.1016/j.prosdent.2018.11.016