Back to Search
Start Over
Position-based modeling of lesion displacement in ultrasound-guided breast biopsy.
- Source :
-
International journal of computer assisted radiology and surgery [Int J Comput Assist Radiol Surg] 2019 Aug; Vol. 14 (8), pp. 1329-1339. Date of Electronic Publication: 2019 Jun 03. - Publication Year :
- 2019
-
Abstract
- Purpose: Although ultrasound (US) images represent the most popular modality for guiding breast biopsy, malignant regions are often missed by sonography, thus preventing accurate lesion localization which is essential for a successful procedure. Biomechanical models can support the localization of suspicious areas identified on a preoperative image during US scanning since they are able to account for anatomical deformations resulting from US probe pressure. We propose a deformation model which relies on position-based dynamics (PBD) approach to predict the displacement of internal targets induced by probe interaction during US acquisition.<br />Methods: The PBD implementation available in NVIDIA FleX is exploited to create an anatomical model capable of deforming online. Simulation parameters are initialized on a calibration phantom under different levels of probe-induced deformations; then, they are fine-tuned by minimizing the localization error of a US-visible landmark of a realistic breast phantom. The updated model is used to estimate the displacement of other internal lesions due to probe-tissue interaction.<br />Results: The localization error obtained when applying the PBD model remains below 11 mm for all the tumors even for input displacements in the order of 30 mm. This proposed method obtains results aligned with FE models with faster computational performance, suitable for real-time applications. In addition, it outperforms rigid model used to track lesion position in US-guided breast biopsies, at least halving the localization error for all the displacement ranges considered.<br />Conclusion: Position-based dynamics approach has proved to be successful in modeling breast tissue deformations during US acquisition. Its stability, accuracy and real-time performance make such model suitable for tracking lesions displacement during US-guided breast biopsy.
Details
- Language :
- English
- ISSN :
- 1861-6429
- Volume :
- 14
- Issue :
- 8
- Database :
- MEDLINE
- Journal :
- International journal of computer assisted radiology and surgery
- Publication Type :
- Academic Journal
- Accession number :
- 31161556
- Full Text :
- https://doi.org/10.1007/s11548-019-01997-z