Back to Search
Start Over
Comparison of Three Different Techniques on the Movement of Implants After Evisceration.
- Source :
-
The Journal of craniofacial surgery [J Craniofac Surg] 2019 Oct; Vol. 30 (7), pp. e590-e593. - Publication Year :
- 2019
-
Abstract
- Purpose: To compare the results of 3 evisceration techniques involving placement of an acrylic implant within the scleral shell without posterior sclerotomy (Group 1), posterior sclerotomy with placement of a porous implant within the intraconal space (Group 2) and posterior sclerotomy with placement of a acrylic implant within the intraconal space (Group 3) with respect to ocular mobility, implant complications and patient satisfaction.<br />Methods: Single-center, retrospective, interventional case series. A chart review of 72 patients undergoing evisceration between February 2013 and January 2018 was carried out. Thirty-five patients met the inclusion criteria having a normal or near normal size eye and at least 6 months follow-up. The horizontal movements of the implant and the artificial eye was measured by using a ruler. Data analyses were conducted using the Mann-Whitney U test for 2 independent samples.<br />Results: Neither infection nor prolapse of the implant had occurred in any of the patients. The mean implant sizes were 18 mm in Group 1, 20 mm in Group 2 and 20 mm in Group 3. Statistically, a significant difference was assessed between Group 1 and Group 2 in both nasal and temporal movement of the socket; nasal and temporal movement of the prosthesis. Statistically, a significant difference was assessed between Group 1 and Group 3 in both nasal and temporal movement of the socket; nasal and temporal movement of the prosthesis. However, there was no statistically significant difference between Group 2 and Group 3 in neither nasal and temporal movement of the socket nor nasal and temporal movement of the artificial eye.<br />Conclusion: Group 1 showed the significantly better movement of both prosthesis and socket in adduction and abduction than Group 2 and 3. The likely explanation for this may be that preserving the scleral shell integrity allows more efficient transmission of muscle contraction to the socket and prosthesis.
Details
- Language :
- English
- ISSN :
- 1536-3732
- Volume :
- 30
- Issue :
- 7
- Database :
- MEDLINE
- Journal :
- The Journal of craniofacial surgery
- Publication Type :
- Academic Journal
- Accession number :
- 31157636
- Full Text :
- https://doi.org/10.1097/SCS.0000000000005584