Use of refractive index measurement for quality assurance of pediatric parenteral nutrient solutions.

Authors :
Meyer GE
Novielli KA
Smith JE
Source :
American journal of hospital pharmacy [Am J Hosp Pharm] 1987 Jul; Vol. 44 (7), pp. 1617-20.
Publication Year :
1987

Abstract

Use of refractive index measurements to assure accurate formulation of pediatric parenteral nutrient base solutions is described. The refractive indexes for various amino acid and dextrose concentrations were determined. An equation was derived to define the theoretical refractive index for combinations of amino acids and dextrose. Finally, a clinically acceptable range (deviation from theoretical) was determined. The actual refractive index for 300 pediatric parenteral nutrient solutions was compared with the calculated theoretical reading. The actual refractive index for all solutions was consistently predicted by the derived equation. Discussions with clinicians resulted in identification of an allowable range for these readings. All reading were within the identified range. The use of refractive index measurements is a valuable quality assurance tool for pediatric parenteral nutrient base formulations.

Details

Language :
English
ISSN :
0002-9289
Volume :
44
Issue :
7
Database :
MEDLINE
Journal :
American journal of hospital pharmacy
Publication Type :
Academic Journal
Accession number :
3115096