Back to Search Start Over

Time-to-isolation-guided cryoballoon ablation reduces oesophageal and mediastinal alterations detected by endoscopic ultrasound: results of the MADE-PVI trial.

Authors :
Cordes F
Ellermann C
Dechering DG
Frommeyer G
Kochhäuser S
Lange PS
Pott C
Lenze F
Schmidt H
Ullerich H
Eckardt L
Source :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2019 Sep 01; Vol. 21 (9), pp. 1325-1333.
Publication Year :
2019

Abstract

Aims: Cryoballoon ablation is safe and efficient for achieving pulmonary vein isolation (PVI) in atrial fibrillation. Structural oesophago-mediastinal lesions, which seem to be associated with an increased risk of the lethal complication of an atrio-oesophageal fistula, have been described. MADE-PVI (Mediastino-oesophageal Alterations Detected by Endosonography after PVI) aimed at evaluating safety of cryoballoon PVI in relation to two different freeze protocols. As time-to-isolation-(TTI)-guided protocol has been reported to be as effective as conventional 'two freeze protocol', we hypothesized a TTI-guided protocol causes less oesophago-mediastinal lesions.<br />Methods and Results: Seventy consecutive patients were scheduled for cryoballoon (2nd generation) PVI employing either a conventional protocol (n = 35: 2 × 180 s per vein) or a TTI-guided approach (n = 35: TTI + 120 s per vein or 1 × 180 s in case TTI could not be measured). Oesophagogastroduodenoscopy and endoscopic ultrasound, assessing oesophago-mediastinal alterations (e.g. ulceration, oedema) were performed blinded prior and post-ablation. Post-interventional mediastinal oedematous alterations were detected in 70% with a mean diameter of 14 mm (±0.9 mm), while only 15% revealed large mediastinal oedema >20 mm. Oesophageal lesions due to PVI occurred in 5%. Freeze protocols had a distinct impact on oesophago-mediastinal alterations as mean diameter and frequency of large oedema were significantly increased in patients after conventional protocol PVI (17 mm vs. 11 mm; 26% vs. 6%). Furthermore, every oesophageal lesion was detected in patients with conventional protocol (9%). No major complication occurred in either group.<br />Conclusion: The present prospective study demonstrates a significant impact of freeze protocol on oesophago-mediastinal alterations. A TTI-guided protocol reduces mediastino-oesophageal lesions and may reduce short- and long-term complications of cryoballoon PVI.<br /> (Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2019. For permissions, please email: journals.permissions@oup.com.)

Details

Language :
English
ISSN :
1532-2092
Volume :
21
Issue :
9
Database :
MEDLINE
Journal :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
Publication Type :
Academic Journal
Accession number :
31143952
Full Text :
https://doi.org/10.1093/europace/euz142