Back to Search Start Over

Performance of wastewater reclamation systems in enteric virus removal.

Authors :
Prado T
de Castro Bruni A
Barbosa MRF
Garcia SC
de Jesus Melo AM
Sato MIZ
Source :
The Science of the total environment [Sci Total Environ] 2019 Aug 15; Vol. 678, pp. 33-42. Date of Electronic Publication: 2019 Apr 30.
Publication Year :
2019

Abstract

Analysis of virus removal by tertiary or advanced sewage treatment processes is an emerging topic due to importance of reusing water on a global level. This study aimed to monitor important human viral pathogens: the human adenovirus (HAdV), JC polyomavirus (JCV) and Species A rotaviruses (RVA) in urban sewage, secondary effluents and reclaimed water from metropolitan São Paulo (MSP), Brazil. Four large wastewater treatment plants (WWTPs) in MSP were sampled monthly during a one-year period (April 2015 to March 2016). The viruses were quantified by quantitative PCR (qPCR), and HAdV viability was tested by the integrated cell culture (ICC)-qPCR assay. WWTPs are composed of activated sludge processes and different tertiary treatments (coagulation/sedimentation, sand-anthracite filters, membrane bioreactors (MBRs)/reverse osmosis (RO) and disinfection by chlorination). Physicochemical parameters were also evaluated to verify association with density of viruses detected in different treatment stages. HAdV, JCV and RVA were consistently detected (100%) in the sewage influent samples (range: 10 <superscript>6</superscript> -10 <superscript>8</superscript> genome copies GC/L). In the secondary effluent, HAdV was detected in 100% (48/48) of the analysed samples, JCV in 85.4% and RVA in 97.9% (range: 10 <superscript>4</superscript> -10 <superscript>7</superscript> GC/L for all viruses tested). HAdV was the most frequently detected virus in the tertiary effluent (62.2%) (28/45), exhibiting a viability between 0 and 44% of the tested samples in the wastewater reclamation systems. The MBR/RO systems demonstrated better virus removal efficiencies (range: 2.3-2.9 log <subscript>10</subscript> ). Temperature, pH, turbidity and total organic carbon presented association with the viral density in the reclaimed water samples. Presence of viruses in treated effluents can indicates health risks depending on uses of recovery water. Further risk assessment studies should be conducted to better assess health risks under different exposure scenarios for water recovery in urban settings.<br /> (Copyright © 2019 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1879-1026
Volume :
678
Database :
MEDLINE
Journal :
The Science of the total environment
Publication Type :
Academic Journal
Accession number :
31075600
Full Text :
https://doi.org/10.1016/j.scitotenv.2019.04.435