Back to Search
Start Over
Threshold Static Automated Perimetry of the Full Visual Field in Idiopathic Intracranial Hypertension.
- Source :
-
Investigative ophthalmology & visual science [Invest Ophthalmol Vis Sci] 2019 May 01; Vol. 60 (6), pp. 1898-1905. - Publication Year :
- 2019
-
Abstract
- Purpose: To characterize visual loss across the full visual field in idiopathic intracranial hypertension (IIH) patients with mild central visual loss.<br />Methods: We tested the full visual field (50° nasal, 80° temporal, 30° superior, 45° inferior) of 1 eye of 39 IIH patients by using static perimetry (size V) with the Open Perimetry Interface. Participants met the Dandy criteria for IIH and had at least Frisén grade 1 papilledema with better than -5 dB mean deviation (MD) centrally. Two observers (MW and AS) evaluated the visual field defects, adjudicated any differences, and reviewed optical coherence tomography data.<br />Results: We found a greater MD loss peripherally than centrally (central 26°). The median MD (and corresponding median absolute deviations) was -1.37 dB (1.61 dB) for the periphery and -0.77 dB (0.87 dB) for the central 26°, P < 0.001. There were about 30% more abnormal test locations identified in the periphery (P = 0.12), and the mean defect depth increased with eccentricity (P < 0.001). The most frequent defect found was a temporal wedge (23% of cases) in the periphery with another 23% that included this sector with inferior temporal loss. Although the presence of papilledema limited correlation, 55% of the temporal wedge defects had optical coherence tomography retinal nerve fiber layer deficits in the corresponding superonasal location. Other common visual field defects were inferonasal loss, superonasal loss, and superior and inferior arcuate defects. Seven patients (18%) had visual field defects in the periphery with normal central visual field testing.<br />Conclusion: In IIH patients, we found substantial visual loss both outside 30° of the visual field and inside 30° with the depth of the defect increasing linearly with eccentricity. Temporal wedge defects were the most common visual field defect in the periphery. Static threshold perimetry of the full visual field appears to be clinically useful in IIH patients.
- Subjects :
- Adult
Female
Humans
Male
Middle Aged
Pseudotumor Cerebri complications
Pseudotumor Cerebri diagnosis
Reproducibility of Results
Retinal Ganglion Cells pathology
Scotoma etiology
Scotoma physiopathology
Tomography, Optical Coherence
Young Adult
Pseudotumor Cerebri physiopathology
Scotoma diagnosis
Visual Field Tests methods
Visual Fields physiology
Subjects
Details
- Language :
- English
- ISSN :
- 1552-5783
- Volume :
- 60
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Investigative ophthalmology & visual science
- Publication Type :
- Academic Journal
- Accession number :
- 31042797
- Full Text :
- https://doi.org/10.1167/iovs.18-26252