Back to Search Start Over

Quantitative analysis of cochlear signal intensity on three-dimensional and contrast-enhanced fluid-attenuated inversion recovery images in patients with Meniere's disease: Correlation with the pure tone audiometry test.

Authors :
Lee J
Kim ES
Lee Y
Lee K
Yoon DY
Ju YS
Lee HJ
Hong SK
Kwon MJ
Source :
Journal of neuroradiology = Journal de neuroradiologie [J Neuroradiol] 2019 Sep; Vol. 46 (5), pp. 307-311. Date of Electronic Publication: 2019 Apr 03.
Publication Year :
2019

Abstract

Purpose: The purpose of this study was to correlate the quantitative analysis of cochlear signal intensity (SI) on 3-dimensional fluid-attenuated inversion recovery (3D-FLAIR) and contrast-enhanced (CE) 3D-FLAIR images with results of the pure tone audiometry (PTA) test in patients with Meniere's disease (MD).<br />Materials and Methods: Over a 3-year period, 123 patients with MD underwent 3-Tesla (3 T) temporal magnetic resonance imaging (MRI), including 3D-FLAIR and CE-FLAIR sequences. The SI of membranous labyrinth of the cochlea in both ears of each patient was measured by drawing a region of interest (ROI) with a seed growing technique. The correlation between measured cochlear SIs on 3D-FLAIR and CE-FLAIR images, contrast enhancement index (CEI), and contrast enhancement ratio (CER) and clinical findings and pre- and post-treatment PTA results were assessed.<br />Results: Cochlear signal ratios of symptomatic ears on 3D-FLAIR and CE-FLAIR images were significantly higher than those of asymptomatic ears (P < 0.001). The area under the curve, from the receiver operating characteristic curve of cochlear SIs on 3D-FLAIR and CE-FLAIR images for discrimination between symptomatic and asymptomatic ears, was 0.729 and 0.728, respectively. Cochlear SIs on 3D-FLAIR and CE-FLAIR images were significantly correlated with patients' sex (P < 0.05 and P < 0.01, respectively), symptomatic ear (both P < 0.0001), and pre-treatment PTA (P < 0.0001 and P < 0.005, respectively), but were not significantly correlated with patients' age, post-treatment PTA or hearing threshold level at 0.5, 1.0, 2.0, or 4.0 kHz.<br />Conclusion: Quantitative analysis of cochlear SI on 3D-FLAIR and CE-FLAIR images may be a helpful diagnostic adjunct for MD, but may be of little value in predicting the prognosis of MD.<br /> (Copyright © 2019 Elsevier Masson SAS. All rights reserved.)

Details

Language :
English
ISSN :
0150-9861
Volume :
46
Issue :
5
Database :
MEDLINE
Journal :
Journal of neuroradiology = Journal de neuroradiologie
Publication Type :
Academic Journal
Accession number :
30953681
Full Text :
https://doi.org/10.1016/j.neurad.2019.03.010