Back to Search
Start Over
Facile and sensitive determination of urinary mandelic acid by combination of metal organic frameworks with microextraction by packed sorbents.
- Source :
-
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences [J Chromatogr B Analyt Technol Biomed Life Sci] 2019 May 01; Vol. 1114-1115, pp. 45-54. Date of Electronic Publication: 2019 Mar 21. - Publication Year :
- 2019
-
Abstract
- In this study, two hybrid metal organic frameworks including MOF-5@ Fe <subscript>3</subscript> O <subscript>4</subscript> -NH <subscript>2</subscript> and MOF-5@ SBA-15 for the first time were synthetized and combined with microextraction by packed sorbent (MEPS) to extract of mandelic acid (MA) from urine samples. The synthetized sorbents were characterized using FE-SEM, XRD and FT-IR techniques. The important parameters in MEPS procedure including sample volume, extraction draw&#95;discard cycles, elution solvent volume and desorption draw-eject cycles were optimized using response surface methodology (RSM) with central composite design (CCD). The results indicated that the volume of elution solvent was the most important parameter in the recovery of MA by MOF-MEPS procedure. The optimized MOF-MEPS method offered an acceptable efficiency for the recovery of MA from urine samples (MOF-5@Fe <subscript>3</subscript> O <subscript>4</subscript> -NH <subscript>2</subscript> and MOF-5@SBA-15: 94.5% and 90.3%, respectively, RSD < 3.54%). The limit of detection (LOD) of MA calculated by MOF-MEPS procedure combined with high performance liquid chromatography for MOF-5@ Fe <subscript>3</subscript> O <subscript>4</subscript> -NH <subscript>2</subscript> and MOF-5@ SBA-15 were calculated to be 0.10 and 0.13 μg mL <superscript>-1</superscript> , respectively. The linearity dynamic ranges (LDRs) determination of urinary MA by MOF-5@ Fe <subscript>3</subscript> O <subscript>4</subscript> -NH <subscript>2</subscript> and MOF-5@ SBA-15 were 0.2-100 and 0.2-90 μg mL <superscript>-1</superscript> , respectively. The results of the present study implied that the proposed technique is a fast and sensitive procedure for extraction and determination of MA from urine samples.<br /> (Copyright © 2019 Elsevier B.V. All rights reserved.)
- Subjects :
- Chromatography, High Pressure Liquid
Humans
Limit of Detection
Linear Models
Male
Mandelic Acids metabolism
Occupational Exposure analysis
Reproducibility of Results
Styrene analysis
Styrene metabolism
Mandelic Acids urine
Metal-Organic Frameworks chemistry
Solid Phase Microextraction methods
Subjects
Details
- Language :
- English
- ISSN :
- 1873-376X
- Volume :
- 1114-1115
- Database :
- MEDLINE
- Journal :
- Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
- Publication Type :
- Academic Journal
- Accession number :
- 30927741
- Full Text :
- https://doi.org/10.1016/j.jchromb.2019.03.023