Back to Search Start Over

Stability and Specificity of Counterfeit Protection System Code.

Authors :
Li JC
Fang F
Han XZ
Li B
Han W
Zhou Q
Source :
Journal of forensic sciences [J Forensic Sci] 2019 Sep; Vol. 64 (5), pp. 1510-1519. Date of Electronic Publication: 2019 Mar 22.
Publication Year :
2019

Abstract

In this study, the stability and specificity of a counterfeit protection system (CPS) code were determined. This research involved an analysis of a counterfeit protection system code unit over time using the pattern location measurement method. We collected 379 sample sheets from 196 printers or photocopiers, covering 14 original brands, including 129 models. There was an interval of at least two months between the collections of samples from each machine. Four types of characteristics were established: CPS pattern unit, distance of the CPS unit, position of dots, size and shape of the dot. Except for the partial changes in the Xerox brand, no other brand exhibited changes over time. This implies that the CPS characteristics are stable. Meanwhile, no correlation was noted between the combinations of the characteristic systems in the collected samples, which implied strong specificity.<br /> (© 2019 American Academy of Forensic Sciences.)

Details

Language :
English
ISSN :
1556-4029
Volume :
64
Issue :
5
Database :
MEDLINE
Journal :
Journal of forensic sciences
Publication Type :
Academic Journal
Accession number :
30901485
Full Text :
https://doi.org/10.1111/1556-4029.14051