Back to Search
Start Over
Defining the incremental value of 3D T2-weighted imaging in the assessment of prostate cancer extracapsular extension.
- Source :
-
European radiology [Eur Radiol] 2019 Oct; Vol. 29 (10), pp. 5488-5497. Date of Electronic Publication: 2019 Mar 18. - Publication Year :
- 2019
-
Abstract
- Objectives: To assess the added value of 3D T2-weighted imaging (T2WI) over conventional 2D T2WI in diagnosing extracapsular extension (ECE).<br />Methods: Seventy-five patients undergoing 3-T MRI before radical prostatectomy were included. PI-RADS ≥ 4 lesions were assessed for ECE on 2D T2W images using a 5-point Likert scale (1 = no ECE, 5 = definite ECE) and the length of tumour prostatic capsular contact. A second read using 3D T2W images and reformats evaluated ECE and the maximal 3D capsular contact length and surface.<br />Results: One hundred six lesions were identified at MRI. ECE was confirmed by histology in 54% (57/106) of lesions and 64% (48/75) of patients. Sensitivity and specificity for 3D T2 reads were 75.4% versus 64.9% (p = 0.058), respectively, and 83.7% versus 85.7% (p = 0.705) for 2D T2 reads, respectively. 3D T2W reads showed significantly higher mean subjective Likert scores of 3.7 ± 1.4 versus 3.3 ± 1.4 (p = 0.001) in ECE-positive lesions and lower mean Likert score of 1.5 ± 1 versus 1.6 ± 0.9 (p = 0.27) in ECE-negative lesions compared with 2D T2W reads. 3D contact significantly increased sensitivity from 59.6 to 73.7% (p = 0.03), whilst maintaining the same specificity of 87.8% (p = 1). High-grade group tumours (≥ Gleason 4 + 3) showed significantly higher ECE prevalence than low-grade tumours (88% versus 44%, p < 0.001) and a positive predictive value (PPV) for ECE of 90.9% with ≥ 5 mm of contact versus PPV of 90.4% at ≥ 12.5 mm for lower grade tumours.<br />Conclusions: 3D T2WI significantly increases sensitivity and confidence in calling ECE. The capsular contact length threshold differed between low- and high-grade cancers.<br />Key Points: • 3D capsular contact length and 3D surface contact significantly increased sensitivity in diagnosing ECE. • 3D T2W reads significantly increased reader confidence in calling ECE. • Thresholds for capsular contact length differed between low-grade and high-grade cancers.
- Subjects :
- Adult
Aged
Humans
Image Interpretation, Computer-Assisted methods
Imaging, Three-Dimensional methods
Magnetic Resonance Imaging methods
Male
Middle Aged
Neoplasm Grading
Neoplasm Invasiveness
Neoplasm Staging
Predictive Value of Tests
Prostatectomy methods
Prostatic Neoplasms pathology
Prostatic Neoplasms surgery
Sensitivity and Specificity
Extranodal Extension diagnostic imaging
Prostatic Neoplasms diagnostic imaging
Subjects
Details
- Language :
- English
- ISSN :
- 1432-1084
- Volume :
- 29
- Issue :
- 10
- Database :
- MEDLINE
- Journal :
- European radiology
- Publication Type :
- Academic Journal
- Accession number :
- 30887192
- Full Text :
- https://doi.org/10.1007/s00330-019-06070-6