Back to Search Start Over

Application of a self-assembling peptide matrix prevents esophageal stricture after circumferential endoscopic submucosal dissection in a pig model.

Authors :
Oumrani S
Barret M
Bordaçahar B
Beuvon F
Hochart G
Pagnon-Minot A
Coriat R
Batteux F
Prat F
Source :
PloS one [PLoS One] 2019 Mar 12; Vol. 14 (3), pp. e0212362. Date of Electronic Publication: 2019 Mar 12 (Print Publication: 2019).
Publication Year :
2019

Abstract

Introduction: Circumferential endoscopic submucosal dissection (ESD) allows to treat large esophageal superficial neoplasms, however with a high occurrence of severe esophageal strictures. In a previous work, we demonstrated that the application of a prototype of self-assembling peptide (SAP) matrix on esophageal wounds after a circumferential-ESD delayed the onset of esophageal stricture in a porcine model. The aim of this work was to consolidate these results using the commercialized version of this SAP matrix currently used as a hemostatic agent.<br />Animals and Methods: Eleven pigs underwent a 5 cm-long circumferential esophageal ESD under general anesthesia. Five pigs were used as a control group and six were treated with the SAP. In the experimental group, 3.5 mL of the SAP matrix were immediately applied on the ESD wound. Stricture rates and esophageal diameter were assessed at day 14 by endoscopy and esophagram, followed by necropsy and histological measurements of inflammation and fibrosis in the esophageal wall.<br />Results: At day 14, two animals in the treated group had an esophageal stricture without any symptom, while all animals in the control group had regurgitations and an esophageal stricture (33 vs. 100%, p = 0.045). In the treated group, the mean esophageal diameter at day 14 was 9.5 ± 1 mm vs. 4 ± 0.6 mm in the control group (p = 0.004). Histologically, the neoepithelium was longer in the SAP treated group vs. the control (3075 μm vs. 1155μm, p = 0.014). On immunohistochemistry, the expression of alpha smooth muscle actin was lower in the treated vs. control group.<br />Conclusion: Apposition of a self-assembling peptide matrix immediately after a circumferential esophageal ESD reduced by 67% the occurrence of a stricture at day 14, by promoting reepithelialization of the resected area.<br />Competing Interests: We have the following interests: The study was funded by 3-D Matrix Europe SAS. Guillaume Hochart is employed by Imabiotech and Aurélie Pagnon-Minot by Novotec. There are no patents, products in development or marketed products to declare. This does not alter our adherence to all the PLOS ONE policies on sharing data and materials, as detailed online in the guide for authors.

Details

Language :
English
ISSN :
1932-6203
Volume :
14
Issue :
3
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
30861007
Full Text :
https://doi.org/10.1371/journal.pone.0212362