Back to Search Start Over

Clinical outcomes of the Lotus Valve in patients with bicuspid aortic valve stenosis: An analysis from the RESPOND study.

Authors :
Blackman DJ
Van Gils L
Bleiziffer S
Gerckens U
Petronio AS
Abdel-Wahab M
Werner N
Khogali SS
Wenaweser P
Wöhrle J
Soliman O
Laborde JC
Allocco DJ
Meredith IT
Falk V
Van Mieghem NM
Source :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2019 May 01; Vol. 93 (6), pp. 1116-1123. Date of Electronic Publication: 2019 Feb 17.
Publication Year :
2019

Abstract

Aims: Patients with bicuspid valves represent a challenging anatomical subgroup for transcatheter aortic valve implantation (TAVI). This analysis evaluated the clinical outcomes of the fully repositionable and retrievable Lotus Valve System in patients with bicuspid aortic valves enrolled in the RESPOND post-market registry.<br />Methods and Results: The prospective, open-label RESPOND study enrolled 1,014 patients at 41 centers in Europe, New Zealand, and Latin America, 31 (3.1%) of whom had bicuspid aortic valves. The mean age in the bicuspid patient cohort was 76.4 years, 64.5% were male, and the baseline STS score was 6.0 ± 10.2. Procedural success was 100%, with no cases of malpositioning, valve migration, embolization, or valve-in-valve. Repositioning was attempted in 10 cases (32.3%). There was one death (3.2%) and one stroke (3.2%) at 30-day follow-up. Mean AV gradient was reduced from 48.7 ± 17.0 mmHg at baseline to 11.8 ± 5.1 mmHg at hospital discharge (P < 0.001); mean effective orifice area (EOA) was increased from 0.6 ± 0.2 cm <superscript>2</superscript> to 1.7 ± 0.4 cm <superscript>2</superscript> (P < 0.001). There were no cases of moderate or severe paravalvular leak (PVL) adjudicated by the core laboratory; four subjects (13.8%) had mild PVL, 5 (17.2%) had trace PVL. The rate of pacemaker (PM) implantation for PM-naïve patients was 22.2% (6/27).<br />Conclusions: Data from the RESPOND registry demonstrate good clinical and echocardiographic outcomes up to 1 year postimplantation in patients with bicuspid aortic valves using the repositionable Lotus Valve.<br /> (© 2019 The Authors. Catheterization and Cardiovascular Interventions published by Wiley Periodicals, Inc.)

Details

Language :
English
ISSN :
1522-726X
Volume :
93
Issue :
6
Database :
MEDLINE
Journal :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Publication Type :
Academic Journal
Accession number :
30773838
Full Text :
https://doi.org/10.1002/ccd.28120