Optimization of Receptor Occupancy Assays in Mass Cytometry: Standardization Across Channels with QSC Beads.

Authors :
Bringeland GH
Bader L
Blaser N
Budzinski L
Schulz AR
Mei HE
Myhr KM
Vedeler CA
Gavasso S
Source :
Cytometry. Part A : the journal of the International Society for Analytical Cytology [Cytometry A] 2019 Mar; Vol. 95 (3), pp. 314-322. Date of Electronic Publication: 2019 Jan 27.
Publication Year :
2019

Abstract

Receptor occupancy, the ratio between amount of drug bound and amount of total receptor on single cells, is a biomarker for treatment response to therapeutic monoclonal antibodies. Receptor occupancy is traditionally measured by flow cytometry. However, spectral overlap in flow cytometry limits the number of markers that can be measured simultaneously. This restricts receptor occupancy assays to the analysis of major cell types, although rare cell populations are of potential therapeutic relevance. We therefore developed a receptor occupancy assay suitable for mass cytometry. Measuring more markers than currently available in flow cytometry allows simultaneous receptor occupancy assessment and high-parameter immune phenotyping in whole blood, which should yield new insights into disease activity and therapeutic effects. However, varying sensitivity across the mass cytometer detection range may lead to misinterpretation of the receptor occupancy when drug and receptor are detected in different channels. In this report, we describe a method for optimization of mass cytometry receptor occupancy measurements by using antibody-binding quantum simply cellular (QSC) beads for standardization across channels with different sensitivities. We evaluated the method in a mass cytometry-based receptor occupancy assay for natalizumab, a therapeutic antibody used in multiple sclerosis treatment that binds to α4-integrin, which is expressed on leukocyte cell surfaces. Peripheral blood leukocytes from a treated patient were stained with a panel containing metal-conjugated antibodies for detection of natalizumab and α4-integrin. QSC beads with known antibody binding capacity were stained with the same metal-conjugated antibodies and were used to standardize the signal intensity in the leukocyte sample before calculating receptor occupancy. We found that QSC bead standardization across channels corrected for sensitivity differences for detection of drug and receptor and generated more accurate results than observed without standardization. © 2019 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of International Society for Advancement of Cytometry.<br /> (© 2019 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of International Society for Advancement of Cytometry.)

Details

Language :
English
ISSN :
1552-4930
Volume :
95
Issue :
3
Database :
MEDLINE
Journal :
Cytometry. Part A : the journal of the International Society for Analytical Cytology
Publication Type :
Academic Journal
Accession number :
30688025
Full Text :
https://doi.org/10.1002/cyto.a.23723