Back to Search
Start Over
Self-contamination during doffing of personal protective equipment by healthcare workers to prevent Ebola transmission.
- Source :
-
Antimicrobial resistance and infection control [Antimicrob Resist Infect Control] 2018 Dec 22; Vol. 7, pp. 157. Date of Electronic Publication: 2018 Dec 22 (Print Publication: 2018). - Publication Year :
- 2018
-
Abstract
- Background: Healthcare workers (HCWs) use personal protective equipment (PPE) in Ebola virus disease (EVD) situations. However, preventing the contamination of HCWs and the environment during PPE removal crucially requires improved strategies. This study aimed to compare the efficacy of three PPE ensembles, namely, Hospital Authority (HA) Standard Ebola PPE set (PPE1), Dupont Tyvek Model, style 1422A (PPE2), and HA isolation gown for routine patient care and performing aerosol-generating procedures (PPE3) to prevent EVD transmission by measuring the degree of contamination of HCWs and the environment.<br />Methods: A total of 59 participants randomly performed PPE donning and doffing. The trial consisted of PPE donning, applying fluorescent solution on the PPE surface, PPE doffing of participants, and estimation of the degree of contamination as indicated by the number of fluorescent stains on the working clothes and environment. Protocol deviations during PPE donning and doffing were monitored.<br />Results: PPE2 and PPE3 presented higher contamination risks than PPE1. Environmental contaminations such as those originating from rubbish bin covers, chairs, faucets, and sinks were detected. Procedure deviations were observed during PPE donning and doffing, with PPE1 presenting the lowest overall deviation rate (%) among the three PPE ensembles ( p <  0.05).<br />Conclusion: Contamination of the subjects' working clothes and surrounding environment occurred frequently during PPE doffing. Procedure deviations were observed during PPE donning and doffing. Although PPE1 presented a lower contamination risk than PPE2 and PPE3 during doffing and protocol deviations, the design of PPE1 can still be further improved. Future directions should focus on designing a high-coverage-area PPE with simple ergonomic features and on evaluating the doffing procedure to minimise the risk of recontamination. Regular training for users should be emphasised to minimise protocol deviations, and in turn, guarantee the best protection to HCWs.<br />Competing Interests: The ethical approval was obtained from the human subject ethics subcommittee of the university [HSEARS20160605001]. All participants provided written informed consent prior to participation in the study.Were taken from each person in the photos.The authors declare that they have no competing interests.Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
- Subjects :
- Adult
Aerosols administration & dosage
Environmental Exposure prevention & control
Female
Hemorrhagic Fever, Ebola prevention & control
Humans
Male
Middle Aged
Random Allocation
Young Adult
Health Personnel education
Hemorrhagic Fever, Ebola transmission
Infectious Disease Transmission, Patient-to-Professional prevention & control
Personal Protective Equipment virology
Subjects
Details
- Language :
- English
- ISSN :
- 2047-2994
- Volume :
- 7
- Database :
- MEDLINE
- Journal :
- Antimicrobial resistance and infection control
- Publication Type :
- Academic Journal
- Accession number :
- 30607244
- Full Text :
- https://doi.org/10.1186/s13756-018-0433-y