Construct validity of a low-cost medium-fidelity endoscopic sinus surgery simulation model.

Authors :
Yoshiyasu Y
Chang DR
Bunegin L
Lin RP
Aden JK
Prihoda TJ
Weitzel EK
McMains KC
Malekzadeh S
Bowe SN
Chen PG
Source :
The Laryngoscope [Laryngoscope] 2019 Jul; Vol. 129 (7), pp. 1505-1509. Date of Electronic Publication: 2018 Dec 21.
Publication Year :
2019

Abstract

Objective: Assess construct validity of a low-cost medium-fidelity silicone injection molded model task trainer for endoscopic sinus surgery (ESS) training.<br />Methods: Fellowship-trained rhinologists, otolaryngology attendings, and otolaryngology residents at various levels of training performed sinus endoscopy and seven procedures on the model. Construct validity was evaluated by comparing novice to various levels of experienced performance using a validated checklist.<br />Results: Thirty-two subjects participated in this study. Otolaryngology attendings and postgraduate year (PGY) 3 to 5 otolaryngology residents significantly outperformed PGY 1 to 2 otolaryngology residents on most tasks in the task-specific checklist.<br />Conclusions: This study demonstrated the construct validity of the low-cost medium-fidelity ESS model.<br />Level of Evidence: NA Laryngoscope, 129:1505-1509, 2019.<br /> (© 2018 The American Laryngological, Rhinological and Otological Society, Inc.)