Back to Search Start Over

Feasibility of a novel dose fractionation strategy in TMI/TMLI.

Authors :
Bao Z
Zhao H
Wang D
Gong J
Zhong Y
Xiong Y
Deng D
Xie C
Liu A
Wang X
Liu H
Source :
Radiation oncology (London, England) [Radiat Oncol] 2018 Dec 17; Vol. 13 (1), pp. 248. Date of Electronic Publication: 2018 Dec 17.
Publication Year :
2018

Abstract

Background: To report our experience in planning and delivering total marrow irradiation (TMI) and total marrow and lymphatic irradiation (TMLI) in patients with hematologic malignancies.<br />Methods: Twenty-seven patients undergoing bone marrow transplantation were treated with TMI/TMLI using Helical Tomotherapy (HT). All skeletal bones exclusion of the mandible comprised the treatment target volume and, for TMLI, lymph node chains, liver, spleen and/or brain were also included according to the clinical indication. Planned dose of 8Gy in 2 fractions was delivered over 1 day for TMI while 10Gy in 2 fractions BID was used for TMLI. Organs at risk (OAR) contoured included the brain, brainstem, lens, eyes, optic nerves, parotids, oral cavity, lungs, heart, liver, kidneys, stomach, small bowel, bladder and rectum. In particular, a simple method to avoid hot or cold doses in the overlapping region was implemented and the plan sum was adopted to evaluate dose inhomogeneity. Furthermore, setup errors from 54 treatments were summarized to gauge the effectiveness of immobilization.<br />Results: During the TMI/TMLI treatment, no acute adverse effects occurred during the radiation treatment. Two patients suffered nausea or vomiting right after radiation course. For the 9 patients treated with TMI, the median dose reduction of major organs varied 30-65% of the prescribed dose, substantially lower than the traditional total body irradiation (TBI). Meanwhile, average biological equivalent doses to OARs with 8Gy/2F TMI approach were not different from the conventional 12Gy/6F TMI approach. In the dose junction region, the 93% of PTV was covered by the prescribed dose without obvious hotspots. For the 27 patients, the overall setup corrections were lower than 3 mm except those in the SI direction for abdomen-pelvis region, demonstrating excellent immobilization.<br />Conclusion: The present study confirmed the technical feasibility of HT-based TMI/TMLI delivering 8-10Gy in 2 fractions over 1 day. For patients undergoing hematopoietic cell transplantation the proposed 8Gy/2F TMI (or 10Gy/2F TMLI) strategy may be a novel approach to improve delivery efficiency, increase effective radiation dose to target while maintaining low risk of severe organ toxicities.

Details

Language :
English
ISSN :
1748-717X
Volume :
13
Issue :
1
Database :
MEDLINE
Journal :
Radiation oncology (London, England)
Publication Type :
Academic Journal
Accession number :
30558631
Full Text :
https://doi.org/10.1186/s13014-018-1201-0