Robot-assisted intravertebral augmentation corrects local kyphosis more effectively than a conventional fluoroscopy-guided technique.

Authors :
Alsalmi S
Capel C
Chenin L
Peltier J
Lefranc M
Source :
Journal of neurosurgery. Spine [J Neurosurg Spine] 2018 Nov 30; Vol. 30 (2), pp. 289-295. Date of Electronic Publication: 2018 Nov 30 (Print Publication: 2019).
Publication Year :
2018

Abstract

OBJECTIVEIntravertebral augmentation (IVA) is a reliable minimally invasive technique for treating Magerl type A vertebral body fractures. However, poor correction of kyphotic angulation, the risk of cement leakage, and significant exposure to radiation (for the surgeon, the operating room staff, and the patient) remain significant issues. The authors conducted a study to assess the value of robot-assisted IVA (RA-IVA) for thoracolumbar vertebral body fractures.METHODSThe authors performed a retrospective, single-center study of patients who had undergone RA-IVA or conventional fluoroscopy-guided IVA (F-IVA) for thoracolumbar vertebral body fractures. Installation and operating times, guidance accuracy, residual local kyphosis, degree of restoration of vertebral body height, incidence of cement leakage, rate of morbidity, length of hospital stay, and radiation-related data were recorded.RESULTSData obtained in 30 patients who underwent RA-IVA were compared with those obtained in 30 patients who underwent F-IVA during the same period (the surgical indications were identical, but the surgeons were different). The mean ± SD installation time in the RA-IVA group (24 ± 7.5 minutes) was significantly shorter (p = 0.005) than that in the F-IVA group (26 ± 8 minutes). The mean operating time for the RA-IVA group (52 ± 11 minutes) was significantly longer (p = 0.026) than that for the F-IVA group (30 ± 11 minutes). All RA-IVAs and F-IVAs were Ravi's scale grade A (no pedicle breach). The mean degree of residual local kyphosis (4.7° ± 3.15°) and the percentage of vertebral body height restoration (63.6% ± 21.4%) were significantly better after RA-IVA than after F-IVA (8.4° ± 5.4° and 30% ± 34%, respectively). The incidence of cement leakage was significantly lower in the RA-IVA group (p < 0.05). The mean length of hospital stay after surgery was 3.2 days for both groups. No surgery-related complications occurred in either group. With RA-IVA, the mean radiation exposure was 438 ± 147 mGy × cm for the patient and 30 ± 17 mGy for the surgeon.CONCLUSIONSRA-IVA provided better vertebral body fracture correction than the conventional F-IVA. However, RA-IVA requires more time than F-IVA.

Details

Language :
English
ISSN :
1547-5646
Volume :
30
Issue :
2
Database :
MEDLINE
Journal :
Journal of neurosurgery. Spine
Publication Type :
Academic Journal
Accession number :
30544363
Full Text :
https://doi.org/10.3171/2018.8.SPINE18197