Back to Search Start Over

Development of a positron emission tomography risks map.

Authors :
Rodríguez Fernández A
Triviño Ibáñez EM
Gómez Río M
Pérez Lázaro JJ
Fernández Ruiz I
Ramírez Navarro Á
García Rivero Y
Córdoba Cañete E
Romero Fernández C
Llamas-Elvira JM
Source :
Revista espanola de medicina nuclear e imagen molecular [Rev Esp Med Nucl Imagen Mol (Engl Ed)] 2019 Jan - Feb; Vol. 38 (1), pp. 38-45. Date of Electronic Publication: 2018 Nov 15.
Publication Year :
2019

Abstract

Patient safety is an essential component of quality of care, especially when the complexity of care has reached extreme levels. Currently achieving this safety is considered a basic strategy of the National Health System. Nuclear Medicine departments have certain peculiarities that make them special in terms of patient safety, with situations that go beyond the common healthcare practice of other departments. Namely, that both encapsulated and non-encapsulated ionizing radiation is used in daily practice, and numerous groups of professionals must be coordinated to undertake positron emission tomography (PET) specifically, from the clinical management unit itself, and from other departments of the hospital (as well as companies outside the hospital itself and the Public Health System). The objective of this paper was to identify the risks to which a patient who is to be explored through PET can be exposed in a Nuclear Medicine department and draw up a risk map for the PET process. The methodology used is part of the proposal of the Ministry of Health (2007), and its practical implementation (given the limited literature available on Nuclear Medicine), follows as far as possible that of related care areas (radiodiagnosis and radiotherapy). For this purpose, a multidisciplinary team of professionals directly related to the PET process was created, using the modal analysis of faults and effects methodology to identify possible failures, their causes and the potential adverse events causing each. As a final step, a risk map was created, locating the previously identified faults at each stage of the process. This paper exposes the PET process, and describes the risks that patients might run when a PET scan is required, as well as the adverse events deriving from it. All this is shown in a risk map of the PET process.<br /> (Copyright © 2018 Sociedad Española de Medicina Nuclear e Imagen Molecular. Publicado por Elsevier España, S.L.U. All rights reserved.)

Details

Language :
English; Spanish; Castilian
ISSN :
2253-8089
Volume :
38
Issue :
1
Database :
MEDLINE
Journal :
Revista espanola de medicina nuclear e imagen molecular
Publication Type :
Academic Journal
Accession number :
30448098
Full Text :
https://doi.org/10.1016/j.remn.2018.09.007