Back to Search Start Over

Anesthetic challenges and outcomes for procedures in the intraoperative magnetic resonance imaging suite: A systematic review.

Authors :
Schroeck H
Welch TL
Rovner MS
Johnson HA
Schroeck FR
Source :
Journal of clinical anesthesia [J Clin Anesth] 2019 May; Vol. 54, pp. 89-101. Date of Electronic Publication: 2018 Nov 08.
Publication Year :
2019

Abstract

Background and Objective: Hybrid operating room suites with intraoperative magnetic resonance imaging enable image guided surgery in a fully functional operating room environment. While this environment creates challenges to anesthetic care, the effects on anesthetic adverse events and outcomes are largely unknown. This systematic scoping review aims to map the existing knowledge about anesthetic care in advanced imaging hybrid operating rooms.<br />Methods: A broad-based literature search was performed using the PubMed (Medline), Embase, Cochrane Library, Web of Science, and Google Scholar databases. References published in English between January 1994 and August 2017 were included. Quality of evidence was assessed using the GRADE guidelines.<br />Results: Forty-seven manuscripts were eligible for data collection. Adverse events were heterogeneously defined across 17 manuscripts and occurred in 0 to 100% (quality of evidence mostly very low). Monitoring difficulty was reported in 4 manuscripts of very low data quality. Interference between the magnet and the electrocardiogram was investigated in 2 manuscripts (quality of evidence low and very low, respectively). None of the reported events appeared to result in long-term patient harm. Author recommendations or a narrative review of the literature were provided in 40 manuscripts. Common safety concerns included lower equipment reliability, inaccessibility of the patient and airway, and the relative isolation of the suite (in relationship to other anesthesia care areas). Most authors also emphasized the importance of safety checklists, protocols, and provider training.<br />Discussion: While intraoperative magnetic resonance imaging hybrid operating rooms are increasingly utilized, the existing literature does not allow estimating adverse event rates in this location. Prospective studies quantifying the effect of the environment on anesthesia outcomes are lacking. Despite this, there is a broad consensus regarding the anesthetic and safety concerns. More research is needed to inform practice standards and training requirements for this challenging environment.<br /> (Copyright © 2018 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1873-4529
Volume :
54
Database :
MEDLINE
Journal :
Journal of clinical anesthesia
Publication Type :
Academic Journal
Accession number :
30415150
Full Text :
https://doi.org/10.1016/j.jclinane.2018.10.022