Back to Search Start Over

Evaluation-independent system for DNA section amplification.

Authors :
Lee DJ
Kim JD
Kim YS
Song HJ
Park CY
Source :
Biomedical engineering online [Biomed Eng Online] 2018 Nov 06; Vol. 17 (Suppl 2), pp. 150. Date of Electronic Publication: 2018 Nov 06.
Publication Year :
2018

Abstract

Background: In general, the image analysis of nucleic acid for detecting DNA is dependent on the gel documentation system. These experiments may deal with harmful staining agents and are time consuming. To address these issues, real-time polymerase chain reaction (PCR) devices have been developed. The advantages of real-time PCR are its capabilities for real-time diagnosis, improved sensitivity, and digitization of measurement results. However, real-time PCR equipment is still too bulky and expensive for use in small hospitals and laboratories.<br />Methods: This paper describes an evaluation-independent real-time PCR system that differs from conventional systems in that it uses a side-illumination optical detection system and a temperature adjustment coefficient for DNA detection. The overall configuration of the evaluation-independent system includes the PCR chip and system hardware and software. The use of the side-illumination method for detection enables the system size to be reduced compared to systems using a typical illumination method. Furthermore, the results of a PCR test are strongly affected by the reaction temperature. Thus, extremely precise control of the temperature of the reaction is needed to obtain accurate results and good reliability. We derived a temperature compensation coefficient that allows us to compensate for the differences between the measured temperature of the negative temperature coefficient (NTC) thermistor sensor and the real temperature of the thermocouple.<br />Results: Applying the temperature compensation coefficient parameter using the NTC thermistor and using the side-illumination method resulted in an increase in the initial sensor value. The occurrence of the DNA section amplification decreased to 22 cycles from 24 cycles.<br />Conclusions: The proposed system showed comparable performance to that of an existing real-time PCR, even with the use of simpler and smaller optical devices.

Details

Language :
English
ISSN :
1475-925X
Volume :
17
Issue :
Suppl 2
Database :
MEDLINE
Journal :
Biomedical engineering online
Publication Type :
Academic Journal
Accession number :
30396354
Full Text :
https://doi.org/10.1186/s12938-018-0580-7