Parafoveal Retinal Vessel Density Assessment by Optical Coherence Tomography Angiography in Healthy Eyes.

Authors :
Arya M
Rebhun CB
Alibhai AY
Chen X
Moreira-Neto C
Baumal CR
Reichel E
Witkin AJ
Duker JS
Sadda SR
Waheed NK
Source :
Ophthalmic surgery, lasers & imaging retina [Ophthalmic Surg Lasers Imaging Retina] 2018 Oct 15; Vol. 49 (10), pp. S5-S17.
Publication Year :
2018

Abstract

Background and Objective: To assess variability in vessel density (VD) measurements across three optical coherence tomography angiography (OCTA) devices to identify a methodology that offers the least amount of variation in VD, and to assess the effect of averaging of multiple scans on VD variability.<br />Patients and Methods: Fifteen eyes of eight healthy individuals were imaged consecutively on three OCTA devices. Segmentations at the superficial, deep, and full retinal layers were generated. Repeat scans for each retinal layer were registered and averaged to generate one OCTA image. Two different automated thresholding techniques were used to calculate vessel area density (VAD) from binarized images and vessel skeleton density (VSD) from skeletonized images. Vessel length, a linear measure of the combined lengths of vessels, was calculated. Foveal avascular zone (FAZ) area was measured.<br />Results: All three OCTA devices were significantly different (P < .0001). This finding remained after averaging images (P < .0001). VSD was more repeatable within a device but less reproducible across devices. Conversely, VAD demonstrated less repeatability but greater reproducibility. Differences in VSD between devices were systematic and attributable to differences in resolution. Vessel length, unaffected by resolution, demonstrated no significant differences between the devices (P > .107). There was no significant difference in FAZ area across devices (P = .51). After averaging images, VD was significantly different from the single images for each device and plexus (P < .05) but remained within 1% of the value of a single scan.<br />Conclusions: OCTA devices show variability in VD for healthy individuals. With greater repeatability, VSD appeared useful for following a patient on one device. VAD and vessel length seemed ideal for comparing vessel parameters between OCTA devices. After averaging multiple scans, VSD remained within 1% of a single scan, for which clinical significance remains to be determined. Caution is advised when comparing quantitative analyses across OCTA devices. [Ophthalmic Surg Lasers Imaging Retina. 2018;49:S5-S17.].<br /> (Copyright 2018, SLACK Incorporated.)

Details

Language :
English
ISSN :
2325-8179
Volume :
49
Issue :
10
Database :
MEDLINE
Journal :
Ophthalmic surgery, lasers & imaging retina
Publication Type :
Academic Journal
Accession number :
30339262
Full Text :
https://doi.org/10.3928/23258160-20180814-02