Back to Search
Start Over
Safety of D-dimer testing as a stand-alone test for the exclusion of deep vein thrombosis as compared with other strategies.
- Source :
-
Journal of thrombosis and haemostasis : JTH [J Thromb Haemost] 2018 Dec; Vol. 16 (12), pp. 2471-2481. Date of Electronic Publication: 2018 Nov 20. - Publication Year :
- 2018
-
Abstract
- Essentials The aim of deep vein thrombosis (DVT) diagnostic work-up is to maximize both safety and efficiency. We explored whether D-dimer is safe and efficient as a stand-alone test to exclude DVT. Our findings suggest it is a safe, efficient and simplified diagnostic strategy. The safety of age-adjusted D-dimer as a stand-alone test requires further investigation. SUMMARY: Background Several strategies for safely excluding deep vein thrombosis (DVT) while limiting the number of imaging tests have been explored. Objectives To determine whether D-dimer testing could safely and efficiently exclude DVT as a stand-alone test, and evaluate its performance as compared with strategies that incorporate the Wells score and age-adjusted D-dimer. Patients/Methods We included consecutive outpatients referred with suspected DVT to the Emergency Department at Østfold Hospital, Norway. STA-Liatest D-Di PLUS D-dimer was analyzed for all patients. Patients with a D-dimer level of ≥ 0.5 μg mL <superscript>-1</superscript> were referred for compression ultrasonography (CUS). In patients with a D-dimer level of < 0.5 μg mL <superscript>-1</superscript> , no further testing was performed and anticoagulation was withheld. Patients were followed for 3 months for venous thromboembolism (VTE). Results Of the 913 included patients, 298 (33%) had a negative D-dimer result. One hundred and seventy-three patients (18.9%) were diagnosed with DVT at baseline. One of 298 patients had DVT despite having a negative D-dimer result, resulting in a failure rate of 0.3% (95% confidence interval [CI] 0.1-1.9%). Adding the modified Wells score would have yielded a failure rate of 0.0% (95% CI 0.0-1.8%) while necessitating 87 more CUS examinations. Age-adjusted D-dimer as a stand-alone test would have necessitated 80 fewer CUS examinations than fixed D-dimer as a stand-alone test, at the cost of a failure rate of 1.6% (95% CI 0.7-3.4%). Conclusions This outcome study shows that a negative high-sensitivity D-dimer result safely excludes DVT in an outpatient population, and necessitates fewer CUS than if used in combination with Wells score. The safety of stand-alone age-adjusted D-dimer needs further assessment in prospective outcome studies.<br /> (© 2018 International Society on Thrombosis and Haemostasis.)
Details
- Language :
- English
- ISSN :
- 1538-7836
- Volume :
- 16
- Issue :
- 12
- Database :
- MEDLINE
- Journal :
- Journal of thrombosis and haemostasis : JTH
- Publication Type :
- Academic Journal
- Accession number :
- 30303610
- Full Text :
- https://doi.org/10.1111/jth.14314