Back to Search
Start Over
Toward Higher Sensitivity in Quantitative MALDI Imaging Mass Spectrometry of CNS Drugs Using a Nonpolar Matrix.
- Source :
-
Analytical chemistry [Anal Chem] 2018 Nov 06; Vol. 90 (21), pp. 12592-12600. Date of Electronic Publication: 2018 Oct 12. - Publication Year :
- 2018
-
Abstract
- Tissue-specific ion suppression is an unavoidable matrix effect in MALDI mass spectrometry imaging (MALDI-MSI), the negative impact of which on precision and accuracy in quantitative MALDI-MSI can be reduced to some extent by applying isotope internal standards for normalization and matrix-matched calibration routines. The detection sensitivity still suffers, however, often resulting in significant loss of signal for the investigated analytes. An MSI application considerably affected by this phenomenon is the quantitative spatial analysis of central nervous system (CNS) drugs. Most of these drugs are low molecular weight, lipophilic compounds, which exhibit inefficient desorption and ionization during MALDI using conventional polar acidic matrices (CHCA, DHB). Here, we present the application of the (2-[(2 E)-3-(4- tert-butylphenyl)-2-methylprop-2-enylidene]malononitrile) matrix for high sensitivity imaging of CNS drugs in mouse brain sections. Since DCTB is usually described as an electron-transfer matrix, we provide a rationale (i.e., computational calculations of gas-phase proton affinity and ionization energy) for an additional proton-transfer ionization mechanism with this matrix. Furthermore, we compare the extent of signal suppression for five different CNS drugs when employing DCTB versus CHCA matrices. The results showed that the signal suppression was not only several times lower with DCTB than with CHCA but also depended on the specific tissue investigated. Finally, we present the application of DCTB and ultrahigh resolution Fourier transform ion cyclotron resonance mass spectrometry to quantitative MALDI imaging of the anesthetic drug xylazine in mouse brain sections based on a linear matrix-matched calibration curve. DCTB afforded up to 100-fold signal intensity improvement over CHCA when comparing representative single MSI pixels and >440-fold improvement for the averaged mass spectrum of the adjacent tissue sections.
- Subjects :
- Animals
Brain Chemistry
Calibration
Central Nervous System Agents chemistry
Clonidine analysis
Clonidine chemistry
Clozapine analysis
Clozapine chemistry
Hydrophobic and Hydrophilic Interactions
Imipramine analysis
Imipramine chemistry
Ketamine analysis
Ketamine chemistry
Limit of Detection
Mice, Inbred C57BL
Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization instrumentation
Xylazine analysis
Xylazine chemistry
Central Nervous System Agents analysis
Nitriles chemistry
Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization methods
Subjects
Details
- Language :
- English
- ISSN :
- 1520-6882
- Volume :
- 90
- Issue :
- 21
- Database :
- MEDLINE
- Journal :
- Analytical chemistry
- Publication Type :
- Academic Journal
- Accession number :
- 30260620
- Full Text :
- https://doi.org/10.1021/acs.analchem.8b02740