Back to Search Start Over

Prevalence of exertional oscillatory ventilation in continuous-flow left ventricular assist device recipients.

Authors :
Pistono M
Gnemmi M
Imparato A
Komici K
CorrĂ  U
Source :
European journal of preventive cardiology [Eur J Prev Cardiol] 2018 Nov; Vol. 25 (17), pp. 1838-1842. Date of Electronic Publication: 2018 Sep 24.
Publication Year :
2018

Abstract

Background: Exercise oscillatory ventilation is an ominous outcome sign in heart failure due to reduced left ventricular ejection fraction; currently, the prevalence of exercise oscillatory ventilation is unknown in left ventricular assist device recipients.<br />Methods: We studied cardiopulmonary exercise testing in heart failure due to reduced left ventricular ejection fraction or left ventricular assist device patients and exercise oscillatory ventilation was defined according to Kremser's criteria.<br />Results: The occurrence of exercise oscillatory ventilation was similar in either heart failure due to reduced left ventricular ejection fraction (192 patients, 8%) or left ventricular assist device patients (85 recipients, 10%), even though the mean peak oxygen consumption and elevated ventilatory response to exercise slope was lower and higher in left ventricular assist device recipients, respectively, but the occurrence of exercise oscillatory ventilation was comparable among heart failure patients due to reduced left ventricular ejection fraction and left ventricular assist device, if those with impaired exercise capacity were considered. Of note, left ventricular assist device recipients with exercise oscillatory ventilation had a higher end-diastolic left ventricular volume and systolic pulmonary artery pressure at rest.<br />Conclusions: Using the largest cohort of left ventricular assist device patients performing cardiopulmonary exercise testing, we demonstrated that the occurrence of exercise oscillatory ventilation is similar in heart failure due to reduced left ventricular ejection fraction and left ventricular assist device patients. Recipients with exercise oscillatory ventilation might have haemodynamic and ventilatory dysfunction during exercise, but other factors could play a role, i.e. the duration and severity of heart failure before left ventricular assist device implantation together with the coexistence of morbidity.

Details

Language :
English
ISSN :
2047-4881
Volume :
25
Issue :
17
Database :
MEDLINE
Journal :
European journal of preventive cardiology
Publication Type :
Academic Journal
Accession number :
30247070
Full Text :
https://doi.org/10.1177/2047487318801415