Back to Search Start Over

Rigid motion-corrected magnetic resonance fingerprinting.

Authors :
Cruz G
Jaubert O
Schneider T
Botnar RM
Prieto C
Source :
Magnetic resonance in medicine [Magn Reson Med] 2019 Feb; Vol. 81 (2), pp. 947-961. Date of Electronic Publication: 2018 Sep 03.
Publication Year :
2019

Abstract

Purpose: Develop a method for rigid body motion-corrected magnetic resonance fingerprinting (MRF).<br />Methods: MRF has shown some robustness to abrupt motion toward the end of the acquisition. Here, we study the effects of different types of rigid body motion during the acquisition on MRF and propose a novel approach to correct for this motion. The proposed method (MC-MRF) follows 4 steps: (1) sliding window reconstruction is performed to produce high-quality auxiliary dynamic images; (2) rotation and translation motion is estimated from the dynamic images by image registration; (3) estimated motion is used to correct acquired k-space data with corresponding rotations and phase shifts; and (4) motion-corrected data are reconstructed with low-rank inversion. MC-MRF was validated in a standard T <subscript>1</subscript> /T <subscript>2</subscript> phantom and 2D in vivo brain acquisitions in 7 healthy subjects. Additionally, the effect of through-plane motion in 2D MC-MRF was investigated.<br />Results: Simulation results show that motion in MRF can introduce artifacts in T <subscript>1</subscript> and T <subscript>2</subscript> maps, depending when it occurs. MC-MRF improved parametric map quality in all phantom and in vivo experiments with in-plane motion, comparable to the no-motion ground truth. Reduced parametric map quality, even after motion correction, was observed for acquisitions with through-plane motion, particularly for smaller structures in T <subscript>2</subscript> maps.<br />Conclusion: Here, a novel method for motion correction in MRF (MC-MRF) is proposed, which improves parametric map quality and accuracy in comparison to no-motion correction approaches. Future work will include validation of 3D MC-MRF to enable also through-plane motion correction.<br /> (© 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.)

Details

Language :
English
ISSN :
1522-2594
Volume :
81
Issue :
2
Database :
MEDLINE
Journal :
Magnetic resonance in medicine
Publication Type :
Academic Journal
Accession number :
30229558
Full Text :
https://doi.org/10.1002/mrm.27448